As all us know that the capacitor panel is connected to improve the power factor when it is PF is low. whether we can connect the capacitor panel on D.G. side(? If it is yes means why?
1 6451HOW TO CALCULATE THE CAPACITOR RANGE FOR LOAD FOR PF IMPROVEMENT? EXPLE:FOR 65 HP LOAD HOW TO CALCULATE CAPACITOR RANGE?
Al-Malik, All Star Electric, GEC, Reliance, Universal Industries,
12 46550what is full form of lv and mv? 2.while we connect capacitor to generator what will cause for it?
4 32221how to find motor contactor rating and bimetalic relay rating? of 30kw motor which will operate on star-delta starter?
6 21885hw to find transformer is in normal position? whether its in charged condition or not? except humming sound?
ABB,
9 14550How can we calculate the fault level of the distribution system knowing the percentage impedance of transformer & subsequent equipments.
14 60479whether the generating voltage can be made to be transmitted by means of signals to the recieved end or at the consumers end?
TCS,
6 9630Post New Electrical Engineering Questions
Define newton's law of viscosity.
why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?
HOW TO CALCULATE THE VT SIZING?
WHY BREAKER ARE USED IN SUBSTATIONS?
What information we need to prepare relay coordination chart
Can clean earth cable be considered as low current cable
Incoming line 11kv And transformer capacity is 2500kva. Consumption load is 1300A. Then fuse capacity is 11kv line.
what is meant by neutral compensation factor and where it is used
how is the testing of an REF relay? what are the test REF circuit having?
If the earth is a good conductor of electricity, why don't people get shocked every time they walking on earth?
I'm looking for a softcopy manual set for a Credence ASL- 3000. Anyone know where I can get it?
What is quadrantal symmetry?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what are the assumptions made in swineburne's test?
In CTs tan delta point should be earthed , what is the reason behind it?