132/6.6ππ πππππππππππ πππππππ πππ πππ πππππ πππ πππππππππ. πΈ'ππ πππππππ πππππππππππ ππ 6.6ππ/415π πππ πΈ πππππππ πππππππ ππ ππππ πππππ πππ ππ ππ 13/6.ππ πππππππππππ?? πΈπ π½π.. ππππ π ππ’??
573how to calculate diesel consumption of diesel generator by considering load and capacity of generator?
1 990What is the different between conventional MCC and intelligent MCC? Common controller or controller for each bucket
568What kind of socket shall be provided for window type air conditioner with cooling capacity upto 18000 BTU/hr
641The inventer is a battery, but if lost current at home u will turn on the fan but the is AC and inventer battery is dc . Then how the fan was rotating. What device Or machine in fan converst the Dc power to Ac power
598How does frequency affect KVA rating of a transformer? If a 500 kva, 500 to 250 v, 60 hz t/f normally used in Canada is to be operated in Europe on 50 hz frequency then how will its KVA rating change? a-increase b-decrease c-remains same
1 835How does frequency affect KVA rating of a transformer? If a 500 kva, 500 to 250 v, 60 hz t/f used in Canada is to be operated on 50 hz in Europe frequency then how will its KVA rating change? a-increase b-decrease c-remains same
1 945What is the output of below program?
#include
Post New Electrical Engineering Questions
Earth bits close or open. Which is correct
for what voltage will reactive power be largest in 380 kv line : a) 375kv b)380kv c)385kv
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp β is the cross sectional area of bus bar in millimeters. I - Β Β is the value of AC fault current. t - Β Β is the operating time of disconnecting device in seconds. K β Β is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of βkβ for copper is 143.
66kv under ground cable how to layaing in ground any special case two ckt r runing
As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.
Whether amorphous core transformer is commercialized or not:Name of company making amorphous core transformer and what are different rating?
What is resonant frequency?
what is Fault level? why it is calculated? how will u decide same for our plant?
What is earth?
What are the Full Forms of TVM, MTL, CVT ?
which metal is use in shunt
What is meant by reset level of the relay?
What does the letter CTNM in negative phase sequence relay means?
When steam condenses and becomes water at the same temperature, the specific heat for the process in kJ/kg k is
I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.