Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

ravikumar


{ City } chikmagalur
< Country > india
* Profession * supervisor
User No # 17625
Total Questions Posted # 25
Total Answers Posted # 7

Total Answers Posted for My Questions # 172
Total Views for My Questions # 678199

Users Marked my Answers as Correct # 27
Users Marked my Answers as Wrong # 13
Questions / { ravikumar }
Questions Answers Category Views Company eMail

what is the function of breather in a transformer

Areva, Bhel, RKM Powergen, Vijai Electricals,

29 Electrical Engineering 114707

what is the function of buchhos rely in transformer

5 Electrical Engineering 8365

what is the function of conservater in transformer

3 Electrical Engineering 12739

what is the function of cooling tubes in transformer

4 Electrical Engineering 26837

How silicon gel sucks moisture in the transformer, its have any small exaust fan behind silicon gel.

4 Electrical Engineering 7429

what is the function of starter & choke in the tube light set & how choke give 1000 volts while switching on.

ADNOC Abu Dhabi National Oil Company, IBM,

14 Electrical Engineering 85652

How transformer winding & oil gets heat.

3 Electrical Engineering 6748

what type of transformer used in soft ware parks its distribution or power transformer. like 1800 kva

3 Electrical Engineering 5340

what is the formula to find out how many amps generater takes running on full load.

4 Electrical Engineering 7642

What is the difference between grounding & earthing?

9 Electrical Engineering 22799

How to specific gravity of battery will check, i didnt saw any hydrometer. & say me how to dip into the battery what are the specifications are given in the hydrometer?

1 Electrical Engineering 4107

What is the d/f between DOL & star delta starter & automatic star delta starter?

ACC, Dalkia, Engineering, Indeco, NINL, Novotel, RMH Control Systems, Wipro,

23 Electrical Engineering 164351

What si the d/f b/w KVA & KWH, kvarh & kvar, kwh & kvar phase voltage & line voltage

Indeco,

Electrical Engineering 6083

HOW MANY EARTHINGS REQUIRED FOR GENERATER

Juniper Networks,

10 Electrical Engineering 18559

what is the d/f b/w iverter & converter.

Indeco,

5 Electrical Engineering 7697


 [1]   2    Next



Answers / { ravikumar }

Question { 16622 }

what is electric current


Answer

Flow of electrons in any closed circuit {conducter} is
called electric current.

Is This Answer Correct ?    7 Yes 3 No

Question { Infosys, 21807 }

In winter we seem lightly an electric shock when we touch
to doors(sometime)


Answer

when fuse carry neutral, possible to shock in taps kitchen
equipments etc. solution is fuse should carry phase only.

Is This Answer Correct ?    1 Yes 6 No


Question { Sasken, 8849 }

why generaters need four earthings


Answer

its realy requires four earthing because, two are
platesystem earthing for neutral & two are pipe earthig for
body.

Is This Answer Correct ?    0 Yes 1 No

Question { MacLellan, 116079 }

what is RMU ?


Answer

Ring Main unit, its used at main input to the industries. having the voltage input of 11000 volts. its having two feeders from same sub stations. incase of one feeder fails we may turn on another feeder. high profiles industries & offices using SF6 type of RMUs.

Is This Answer Correct ?    3 Yes 0 No

Question { Genpact, 26990 }

why earthing is not required on transformer prymary winding
side ???


Answer

mr prashanth if u dont know the answer u not suppose to
blame any of the answers.

Is This Answer Correct ?    0 Yes 1 No

Question { ABB, 10064 }

what is difference between fuse and breaker?


Answer

Fuses : fuses break the circuit when only short circuit &
over current flow in the circuit.

Breakers : break the circuit when over voltage, under
voltage, earth fault, over current & its very sensitive.

Fuses : most of the fuses used only at low current rating &
not using at LT panels.

Breakers : its used more high current ratings & using at
all LT panels.

Fuses : fuses made up of Bismuth, Cadmium, Silver & chana
clay.

Breakers : made up of totaly mechanical systems & trpping
coil, closing coil small motors etc.

Fuses : its take very small space to connect

breaker : its take more space to connect.

Is This Answer Correct ?    6 Yes 1 No

Question { 6342 }

what is current


Answer

Flow of electron in any closed circuit is called current.

Is This Answer Correct ?    10 Yes 1 No