what is corona effect?
Answers were Sorted based on User's Feedback
Answer / ranjit kumar mirdha
when between two conductor, the surrounding
medium is ionised and chage are deposite on
the conductor, during this process glow light
with hissing sound. Or when phase voltage is
more than the critical disruptive voltage, at
thats time will corone occure...i.e called
corona..
Is This Answer Correct ? | 1 Yes | 0 No |
Answer / nipan kumar panda
It is the addition of violet glow,hissing noise and
production of ozone gas is an overhead transmission line is
known as corona.
Is This Answer Correct ? | 1 Yes | 0 No |
Answer / sunit chattoraj
A corona is a type of plasma "atmosphere" of the Sun or
other celestial body, extending millions of kilometers into
space, most easily seen during a total solar eclipse, but
also observable in a coronagraph. The Latin root of the
word corona means crown.
Is This Answer Correct ? | 3 Yes | 3 No |
Answer / mahantesh kanthi
CORONA EFFECT OCCURS IN O.H CONDUCTOR, WHEN APPLIED 30 KV /
CM, STARTS MAGNETIC FIELD AROUND IT WHICH ENERGISE THE
VELENCY ELECTRONS AROUND IT, ENERGISED ELECTRON GOT
VELOCITY STRIKES THE NEUTRAL ATOMS, CHARGES ITS FREE
ELECTRONS & THE PROCESS GOES ON THEN STARTS INERACTION WITH
THE PARALLEL CONDUCTOR'S SAME PROCESS, MORE CORONA EFFECT
OCCURS WHEN APPLIED VOLTAGE INCREASED MORE THAN 30 KV / CM,
THE EFFECT WILL BE EVEN MORE, WHERE THE CONDUCTOR DURTY &
COVERED WITH DUST, ALSO OCCURS AT ROUGH SURFACE OF THE
CONDUCTOR, LOOKS IN VIOLET COLOUR THAT TO IN NIGHT,HISSING
SOUND OF CORONA CAN BE HEAR BY DISTANCE.
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / k.c. bankar
When a high voltage transmitted in a
transmission line, due to magnetic effect on the core of
the conductor all most all electrons passes on the surface
of the conductor.And When dielectric voltage becomes more
than 30v\cm . So the air outside the conductor surface
becames conducive and looks bluish and due to dielectric
breakdown of air a hissing noise comes from surrounding,
Called as corona !
Due to corona OZONE formation on the outside surface of the
conductor. The effect of this to the power system is called
as corona effect.
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / pritam halder
When an extra high voltage transmitted in a
transmission line, due to magnetic effect on the core of
the conductor all most all electronics pass on the surface
of the conductor. So the air outside the conductor surface
becames conducive and looks bluish and due to dielectric
breakdown of air a hissing noise comes from surrounding,
Called as corona !
Due to corona OZONE formation on the outside surface of the
conductor. The effect of this to the power system is called
as corona effect.
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / ali chand
the ioization of air molecules around the conductor ,when
the phase voltge is increased beyond certain voltage is
called corona
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / sunny ponna
if we consider two conductors due to potential difference b/w them a violet glow is abserved around the conductor .
if the potential difference is further increased sparkover may happen . this phenomenon is named as corona
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / r.ezhilan
corona effect means long transmission line electro magnetic
field ,So all electron will flow surface of conductor,Some
of electron will try to flow to ground thrugh moisture and
unwanted dust that is called corona effect.
Is This Answer Correct ? | 0 Yes | 0 No |
Answer / pravin kumar singh
In normal atmospheric condition ion & free electron are always present because of cosmic ray , radioactivity,& ultraviolet ray.When a voltage applied to the conductor a potential gradient in the air near to the conductor ,the free electron & ion start moving.But when these voltage increase very high ,the speed of the electron is very high,and they collide with the neutral molecule & disclosed the electron from it & farther electron acquire high speed & start colliding with the other molecules.the process of ionization is cumulative which finely result in electron avalanche.the ionization of air surrounding the conductors give rise the corona effect.
Is This Answer Correct ? | 0 Yes | 0 No |
how many bulb of 60watt at 300volt is used to maintain 0.25 amp.with valid reason?
what is ph test in coolent cheking
what is the significance of 3.5 core cable? or what does this half core mean and why is it required?
How we can design a cable for a 3phase load.
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases voltage A does not alter B decreases C increases D none of above
how to get bearing & winding temperature of an induction motor?
ELECTRICAL DRIVES: can a motor load system with passive load torque can have equilibrium speed in second quadrant
what is meant by fuzzy logic? what is fuzzification and defuzzification?
what is the function of governor in dg set
1 Answers Igarashi, Medispray, Reddy Labs,
Explain the different methods used in the choice of rotor slots for reduction of harmonic torques in an induction motor.
What is Biased Generator Differential Relay?
On wat basis TSM & PSM are set? Example.TSM=30% n PSM=2.5A....Hw they are set and how we come to know that the particular relay should be set to this value only?