Answer Posted / pravin kumar singh
In normal atmospheric condition ion & free electron are always present because of cosmic ray , radioactivity,& ultraviolet ray.When a voltage applied to the conductor a potential gradient in the air near to the conductor ,the free electron & ion start moving.But when these voltage increase very high ,the speed of the electron is very high,and they collide with the neutral molecule & disclosed the electron from it & farther electron acquire high speed & start colliding with the other molecules.the process of ionization is cumulative which finely result in electron avalanche.the ionization of air surrounding the conductors give rise the corona effect.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Define end float in a motor?
what is meaning of sympathetic tripping with respect to relays and give the values for current carrying capacities for copper and aluminium cables from 16sq mm to 500sq mm
Do closed loops systems require manual input?
how can see the ac indoor or out door ac which Tr
what could be the RMS value and average value of a 4 phase sine wave?
1) What are your personal strength? 2) What are your personal areas of improvement? 3) What are your expectations from from a particular job? 4) what are your carrier objectives?
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
PLEASE INFORM ABOUT THE IDEAL TEST RESULTS OF MAGNETIC BALANCE TEST OF TRANSFORMER 33/11 kv DELTA-STAR T/F
When MICC cables used ?
We have 110Vac ,10A ac supply which is converted into 110VDC & How much DC current? which factor is reqired for dc current calulation?
How to calculate VCB rating for 33KV ,25 MW Power line?
WHAT IS THE CURRENT CARRYING CAPACITY OF 2.5/3 CORE HI TUFF CABLE,WILL IT SAFLEY CARRY 8.6 AMPS OVER 120 METRES,CAN YOU ALSO ANSWER WITH FORMULA FOR WORKINGS OUT ,THANK YOU 3RDYR APPRENTICE.
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
how the aircraft outer body and inner body is separated ?
what is the IEC standard for Power Cable installation in onshore (like in direct buried ground or above groung)