why the Steam Turbine(20MW)center line and gear box center line not in same elevation during coupling alignment ?

Answers were Sorted based on User's Feedback



why the Steam Turbine(20MW)center line and gear box center line not in same elevation during coupli..

Answer / dr.atul bansod

Elevation is given for compensation of natural sag of heavy rotors.Steam turbine manufacturer submits a document known as deflection curve for rotors. On that curve '0'point is specified (any bearing) and other bearings ar kept on different elevation with reference to this "0" refereed bearing.

Is This Answer Correct ?    3 Yes 0 No

why the Steam Turbine(20MW)center line and gear box center line not in same elevation during coupli..

Answer / rayudu thota

While rotation high speed shaft of gear box will lift by low speed side shaft due to the load on high speed shaft
Then it will come in to centre line after rotation.

Is This Answer Correct ?    1 Yes 3 No

why the Steam Turbine(20MW)center line and gear box center line not in same elevation during coupli..

Answer / amit singh

It will damage the shaft coupling and more even dangerous in running condition & JOP lifts the shaft not by weight u fool.

Is This Answer Correct ?    0 Yes 2 No

Post New Answer

More Power Plant Engineering Interview Questions

Need of oxygen dosing in super critical powerplants?

5 Answers  


What happen when the AVR of the generator fails? Will it cause power instability and total failure of the alternator?

8 Answers  


A 5A rewirable fuse blows when 9A flows.determine the fusing factor?

1 Answers   Schneider, Student, Tata Power,


explain(why) with circuit for pick up of restricted earth fault protection due to external fault

1 Answers  


Why cold water is used for Boiler Hydro test

1 Answers  






what is actual CAL MODE & cal means?

2 Answers   GIPCL,


2. what is meant by exhausthood temp?

4 Answers   Alstom, ANG, GMR,


what is the difference between compensated & normal drum level in boiler drum?

0 Answers   ARS,


what is the perfect location for furnace draft transmitter in AFBC boiler?

1 Answers  


What will happen if the Air Preheater is placed before the Economiser?

6 Answers   Bhel, KSPL, Tata Power,


procedure of how to generate power in solar plant.

0 Answers  


Why superheated are started before I'd and rd fan?

0 Answers   BCPL,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)