why the Steam Turbine(20MW)center line and gear box center line not in same elevation during coupling alignment ?
Answer Posted / dr.atul bansod
Elevation is given for compensation of natural sag of heavy rotors.Steam turbine manufacturer submits a document known as deflection curve for rotors. On that curve '0'point is specified (any bearing) and other bearings ar kept on different elevation with reference to this "0" refereed bearing.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
why do you consider yourself a suitable candidate for this position
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
can dp type level transmitter work in under vaccum condition
what is the difference between compensated & normal drum level in boiler drum?
How We Calibrate the vaccum transmitter?
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
What is LB-SR.
what is restricted earth fault explain in details
By any way can we increase the B check hours from 300 to 500
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
what is the meaning of SST300 V56A in SIEMENS turbine
what is the trip circuit supervision in an electrical meaning?
our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....