Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why is the vector group analysis done in transformer tests

Answers were Sorted based on User's Feedback



why is the vector group analysis done in transformer tests..

Answer / rasool

1) the purpose of transformers based on vector group. (e-g)
for distribution purpose it is Dyn11

2)when your going to synchronise the two transformers it
must be the same vector group.

3) it is a common point that to measure the place
dispalacement between primary voltage and equlivalent
secondary voltage.

Is This Answer Correct ?    1 Yes 0 No

why is the vector group analysis done in transformer tests..

Answer / nallakumar

It is done basically for to check the magnetically balanced
condition for the two windings as well as for phase angle
displacements for to under go in the parallal operation mode
for a transformer.
it also tells the good comparision between
Delta-star,Star-delta and Star-Star or Delta-Delta.

Is This Answer Correct ?    1 Yes 0 No

why is the vector group analysis done in transformer tests..

Answer / susant kumar acharjya

vector group analysis is to determine the plarity strength between hv side and lv side

Is This Answer Correct ?    0 Yes 0 No

why is the vector group analysis done in transformer tests..

Answer / nissi engg solution krishna

to determine the phase displacement between primary and
sencondary sides

Is This Answer Correct ?    0 Yes 0 No

why is the vector group analysis done in transformer tests..

Answer / pratik patel

For parallel operation of transformer

Is This Answer Correct ?    0 Yes 0 No

why is the vector group analysis done in transformer tests..

Answer / jigar1334

because when we connect transfomer with grid at that time phase angle should be same as grid phase angle if phase angle will different than circulating current will flow

Is This Answer Correct ?    0 Yes 0 No

why is the vector group analysis done in transformer tests..

Answer / amit mathur

It is done basically for to check the magnetically balanced
condition for the two windings as well as for phase angle
displacements for to under go in the parallal operation mode
for a transformer.
it also tells the good comparision between
Delta-star,Star-delta and Star-Star or Delta-Delta.

Is This Answer Correct ?    2 Yes 4 No

why is the vector group analysis done in transformer tests..

Answer / mustaza

How to test the transformer vector group? and why this test
is important.

Is This Answer Correct ?    28 Yes 36 No

Post New Answer

More Electrical Engineering Interview Questions

why power is generatd at 50 hz only..? can we do this on another freq...?

7 Answers  


In a three-phase full converter, output voltage pulsates at frequency of a. f b. 2f c. 3f d. 6f

2 Answers  


How can we increase the capacity of exixting capacitor bank??????????????? PLS. Help

1 Answers  


how do i calc busbar size for a rated current?

1 Answers  


My energy meter ratio is -/110/root 3,1A and connected line CT is 100/1,PT is 11kv/110 so what is the MF for meter

1 Answers   Apollo,


sail kaott diploma ece ke interviw me qus.kis parkar ke aate hai aur G.S me kya puchate hai kya sameedyaan me kis parkar ke qu.puchate hai

0 Answers   Sail,


If one tertiary phase i.e. R,Y or B is earthed of a loaded type tertiary delta connected (Without load)of a power auto transformer, what is its advantage/disadvantage?

0 Answers   Amara Raja,


Dear friends , I am going attend interview for WARTSILA INDIA LIMITED , power plant .Could any 1 pls send me few questions. the area i have to concentrate? please send it to mikalraj@gmail.com. pls help me out

1 Answers  


what are the types of control systems to control the speed of the motor??

1 Answers  


while checking the flourscent tube elctrodes some glow is cominag. this type of glow tube working or not working

1 Answers  


TELL ME WHAT IS INDUCTOR AND CAPACITOR WHAT IS IT BASIC OPERATION ANDFUNCTION?

0 Answers   ABC,


What are various power system instabilities and what are their effects on power system operation?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)