Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why is the vector group analysis done in transformer tests

Answer Posted / amit mathur

It is done basically for to check the magnetically balanced
condition for the two windings as well as for phase angle
displacements for to under go in the parallal operation mode
for a transformer.
it also tells the good comparision between
Delta-star,Star-delta and Star-Star or Delta-Delta.

Is This Answer Correct ?    2 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In AC if the direction of current keeps reversing every half cycle, how does it propogate through the transmission lines?

2140


state the working of discharge lamp?

2020


Is MEN and RCD related to each other ?? IF yes then how??

1872


What is A check, B check, C Check & D check for a diesel Generat

2116


what is the best transformer oil breakdown voltage?

1122


What are the disadvantages of thermal power plant?

1086


In a large office how do we calculate required number of light fittings, assuming fittings are 4x18W or 2x36W fluorescent fitting ?

1870


Load break swicth maintenance procedure.

1763


when will be the iocl interview results ifaced the interview on september 8 th

2185


What type of a DC motor would you use for a lift?

1070


Sir, plz tell me how droop setting is done in parellel operation od DG set ? please give practical example ?

2132


can someone explain that how the speed of the protection system affects the fault level calculation?

2077


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9207


How can we checked Killo Watts of Motor & Alternator?

2147


how to calculate the power factor when instantaneous voltage and current has harmonics in it ?

1951