Why Magnetic Core Balance test is performed only on Star side of Transformer and not on Delta Side of Transformer (Vector Group Dyn11)?
1 3825A simple Question from all.... If Voltage drops then its rated value what will be effect on a Residential load? similarly if voltage rises from its rated value then what will be effects on a load? i know if voltage drops the equipment or device draws more current then its rated what are other reasons ? thanks in advance for ur time.......
1 29022 electric bulbs of 100w,200V are put in series & the combination of each bulb is supplied to 100 V . the power consumption of each bulb will be????????
4 16416Is there any Electrical supervisor license which gives permit to work whole India rather than individual state??
1870explain me the relation between torque, frequency,speed,voltage and current in the 3 phase induction motor?
2253at what rate the micro controller increment its timer....is it 1micro seconds or 1/(12*10^6) seconds
1790L&T ACB C-POWER OF 800A FAULS TRIPING AT THE TIME OF 110KW MOTOR STARTS WITH EARTH FAULT RELEASE
1 3722L&T ACB C-POWER OF 800A FAULS TRIPING AT THE TIME OF 110KW MOTOR STARTS WITH EARTH FAULT RELEASE
1 6352URGENT PLEASE//////////A WORK SHOP IS HAVING A 100 KVA TRANSFORMER 11KV/415 VOLTS, AND THE CONNECTED LOAD OF THE WORK SHOP IS 80 KW WITH INDUCTIVE LOADS, LIGHTING LOADS,ETC., HOW MANY EARTH ELECTRODES ARE NEEDED AND WHAT IS THE EARTH RESISTANCE OF EACH EARTH ELECTRODE AND COMBINED EARTH RESISTANCE in normal soil. AT 11 KV SIDE AND AT LT SIDE. HOW TO CALCULATE.
1 3382IN 500 KVA TRANSFORMER 11KV/415 VOLTS HOW TO CALCULATE THE HT CABLE SIZE AND LT CABLE SIZE FROM TRANSFORMER TO LT PANNEL. AND HOW MANY MAINSWITCHES OR MCBS WITH RATING ARE TO BE PROVIDED
BSF,
2 24496Post New Electrical Engineering Questions
block diagram of 2 ups system connected in hot stand by mode?
how to introduce yourself
i want design of D.C.MOTOR 1HP 960RPM AND 2HP 960RPM ITS URRGENT
i need the details about bhel exam.how to apply for that.please send to my email-id.thenmozhi2k7@gmail.com
how can i improve the power factor in domestic (230v)
if in 3-phase system voltage=440V,frequency=60Hz, current=400A. then if it is single phase then current=? and if it is single phasing then current=?
What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)
Hi,I am working in abroad for more than 3 years in a company operating with 11kv and 6.4 MW power. I need c licence in India,can I? some other says only i can get if i work for 2 years in india only! anybody kindly clarify by doubt.Thanks
how can decide the current rating of oltc
WILL SCHNEIDER MAKE ACB(MASTERPACT)TRIP ON REVERSE POWER?
Which contains in POLE ASSEMBLY of a 11KV Kirloskar-make SF6 (Model No-FP620A12)? Will u clarify with drawing?
Pls mail me utility & Dg related question with answer
How to know Resistance and Reactance value of main and aux winding of single phase capacitor start capacitor run induction motor to find capacitor value?
current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer
how calculate gd2 of ht motors