Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

HOW TO CALCULATE THE CABLE SIZE FOR POWER CABLE, CONTROL CABLE AND INSTRUMENT CABLE

CA,

2 11231

what is the difference between KW and KVA?

15 69568

how do find power factor in practically and what it means?

3 7873

why transformer rating in kva ?

Eltel, RRB,

14 24076

Why the transformer rating is denoted in VA rating why not in KW

7 16480

what are the types used for alternator earthing,what will happen if more than two alternator is working in parallel with each having own system earthing.is there any possibility for circulating current in between two system.

BEL,

3 10782

What is the reactive power and how to control the reactive power in power plant

14 27057

Why we should use delta connection in primary and star connection in an distribution transformer, which converts 400v a.c. voltage to 33kv.

ABC, Kirloskar, Sify,

15 49236

What is the difference between CRNO and CRGO in an transformer and what is the advantages of these two.

Anchor, CIL, ETA, Kirloskar,

13 73745

sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in

HPCL,

2030

i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately

Bhel,

1977

in india,we use 230V,50 Hz,whereas many other countries use 110V,60Hz.what r d advs and disadvantages of each of them?

11 28244

What is the difference between Neutral and Earth

Bhel,

6 11588

How do you select a cable size(cu and Al) for a particular load

Pepsi,

6 13550

How do you select a cable size(Cu&Al) for a particular load

Adhunik, BPCL Bharat Petroleum, Hiecon, TATA,

10 33499


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

why is the power generator connected as star earthed or star earthed through reactance and what its features ?

1685


As per the Anchor capstan motor specification, full load current is 200A. starting current is 1750 A and acceleration time is less than 8 seconds. Please guide for selection of cable size.

1849


What is current & voltage ? Voltage perform at any load without current or not?

1881


can u please mail me the syllabus for GET exam for damodar valley corporation?

2074




2145


How maesure earth neutral value & how much maximum value value required in between earth & neutral.

2075


how to select the mpcbs and contactor for 3 phase 30 hp star delta motors.for plc control.and tell me the calaculation for future use.

1972


How to address the servo drive for motor

2015


Why PS class CT is always preferred for Differential protection?

1601


Which type of transformer is used for lighting loads?

1136


A 15 kw squirrel cage motor having a maximum efficiency of 90% on a continuous full load has temperature rise of 42 degrees celcius after 30 min and 52 degrees celcius after 1 hr under the above operation conditions. a) calculate its final steady state temperature rise on continuous load and the heating time constatnt. b) if the motor is operated on a short load for 9 min estimate its temperature rise. c) calculate the maximum overload that can be applied on a short, 9 min rating so that the temperature rise is the same as the final steady state temperature rise on continuous load.

1108


How we select the vector group of 3phase power transformer?

2735


How do you select the pickup value of the relay?

1334


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1872


what is the formula for hv test for cable and circuit breaker..????

2040