Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Can Induction motor run at over rated speed? ( 15oo rpm is rated speed for 50HZ. is it possible to ride 3000 RPM with same motor with the help of VVVFD for continues ride of 100HZ)

Equate,

3 9549

HT motors are generally connected in star, what will be the effect if we connect HT motor in Delta?

Equate, Ion Exchange,

6 17435

What is the magnetic field (coil DC ) of Turbo Expander?

TATA,

2073

What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one)

Equate,

2162

What the main causes of transient interruptions on Over-Head Distribution Lines?

Orion Laboratories,

2143

how we can select a transformer based on a particular load. suppose we have 4 motors of rating 40 h.p , 50 h.p, 80 h.p & 100 h.p. then what rating of transformer we can select. urgent. pls reply

6 20253

pls give proper discription of selection of transformer based on particular load.

1 3767

what is a reactive power? what is the relation with power factor?

2187

How can we calculate the motor frame sizes?

Essar,

3409

when we are going to higher voltage level in substations why we are using Sf6 circuit breakers instead of Vacuum circuit breakers.

3 6016

what is the formula to calculate the fuel consumption of a diesel generator at different diferent load.

Aegis, Network Clothing Company,

4 24881

what is a difference b/w earthing & neutral?

ABB, KEC, Sterlite,

5 11884

why we used star delta starter for above 5hp motors

2 7747

Hi Recently I got one formula that is Impedence of Xformer = Rated KVA/Root 3 * secondry voltage OF Xformer. Is it Right??????

2 4886

Why Powers are named in MW?

1 4485


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

what is the difference between vector scale and vector diagram?

4460


What are the basic elements used for modeling mechanical rotational system?

1107


what is the major difference between LIBBP & HIBBP.. which one is most preferable..

2984


An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.

1422


We need to current density & short circuit calculation at 65kA for aluminium & copper busbar.

1744


How o select the electrical fuse?.What are its characteristics.How to select the material od fuse?

1981


How can we measure earthing resistance test (Earth meggar) of Transformer neutral pit while in live condition?.

2139


What is the practical way to calculate the cable size for known ampere load?

1435


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2216


What is phenomenon of electromagnetic induction and how it works?

1072


What is the effect of interchanging core(made of steel) and winding(made of copper) material in case of transformer? Give proper explanation in regard to different losses in transformer.

1877


how we calculate the withstansing current capacity of wires&cables?

2015


Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?

2195


Why only sinusoidal ac voltages are generated?why not triangular or sawtooth?

2092


Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?

1481