In ECC6 can we change the number of dialog workprocesses
without restarting the system and with out using operation
modes?
Answers were Sorted based on User's Feedback
Answer / r. ashok kumar
Yes we can change the number of work process in RZ10. But to
get into use of newly created work process, We should
restart the Application Server.
Is This Answer Correct ? | 6 Yes | 2 No |
Answer / imran
RZ04 is used to define operation modes
and the distribution can be changed in SM63
Is This Answer Correct ? | 3 Yes | 0 No |
Answer / naveen
The procedure to make more work processes available is implemented in two stages:
Reserved (restricted) work processes:
In addition to familiar work process types (dialog, background, spool, and so on), there is also the type reserved. The number of initial work processes (as with the other types also) is specified in the profile parameter rdisp/wp_no_restricted. No further reserved WPs can be created while the system is running.
Reserved work processes are always of the dialog type. They are kept free in normal operation and not used until the system identifies a bottleneck and needs additional work processes to remove it.
Work processes started dynamically If the dynamic work processes are active (rdisp/dynamic_wp_check=TRUE), the system can start new work processes up to the limit specified in rdisp/wp_max_no in order to resolve deadlocks. Dynamic work processes can have different types (dialog, batch, update, and so on).
No reserved work processes are configured in the standard setting (rdisp/no_restricted = 0), but up to two work processes can be started dynamically rdisp/max_wp_no=<Sum of all configured WPs + 2>).
The values would be stranded 2 to 600 wp
This can be changed in RZ11
Newly added parameters:
rdisp/wp_no_restricted
rdisp/wp_max_no
rdisp/dynamic_wp_check
rdisp/max_dynamic_wp_alive_time
rdisp/configurable_wp_no
Is This Answer Correct ? | 3 Yes | 0 No |
Answer / sudheer.y
Through RZ04 you can increase and decrease the DIA & BG
Processes in ECC6-Sudheer-TechM
Is This Answer Correct ? | 9 Yes | 13 No |
Answer / ganesh varma
Yes, we can by using the Transaction RZ11.
In RZ11 most of the parameters doesn't require restart of
the system.
Is This Answer Correct ? | 3 Yes | 7 No |
how do you troubleshoot when user complains that he ii not getting sap portal
Diff between local client copy and remote client copy?
Hai which kernel version, and patch version and now in real time we need to apply? ie means which version is now running on real time?
How to do transport at OS level?
What are homogeneous copy and heterogeneous copy and how you will do that? how to impot the OSS notes? What is OCS how to apply OCS patches? ABAP service pack level can found in SPAM, but how to find the java stack level?
How to restrict particular Tcode in Role. while these not assignsed in role?
Advantage of central instance on application server
WHAT ARE THE STEP BY STEP PROCESS TO APPLY PATCHES ON SAP R/3 SYSTEM?
6 Answers Accenture, Collabera,
What is the difference between – support package, kernel and sap note?
how do u relese chage request? is it possible to relese change request without relesing task?explain step by step
Explain the developer trace?
Explain Client Export in SAP?