why the steam turbine is not operated in home(base) load
more than 1 hour kindly calrify
Answers were Sorted based on User's Feedback
Answer / hardik085
because churning will come and hp exhaust temperature will go high
| Is This Answer Correct ? | 12 Yes | 3 No |
Answer / rana m saqib
steam flow is the cooling media of a turbine.when steam flow will be decrease then temperature of turbine last blade will be increase.
| Is This Answer Correct ? | 5 Yes | 0 No |
Answer / yogesh k. patil.
During underload or FSNL operation, Exhaust steam temperature increases as less heat is converted into electrical energy.Underload operation of steam turbine,like 0.9MW for a 20MW turbine is allowed for 1hrs by manufactures like seimens for SST300 turbine.But in case of emergency wher exhaust hood cooling is impelmented, that can be extended.
| Is This Answer Correct ? | 3 Yes | 0 No |
What is excitation current and voltage in hydro power plant ?
What is MFT and when it is acted.
How to calculate power press toneage
what is under voltage protection 27
Why superheated are started before I'd and rd fan?
What should be the neutral and body grounding sysytem for grid (132 KV) parallel generators (440 volts)?
What is critical speed of turbine
.What do you mean by Turbine Dump.
Need of oxygen dosing in super critical powerplants?
what is interview question for power plant
3 Answers Emerson, IOCL, SBPIL,
why do you consider yourself a suitable candidate for this position
0 Answers Amazon, Eskom, Nabard,
Why reheater is not used after IP turbine.
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)