Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the steam turbine is not operated in home(base) load
more than 1 hour kindly calrify

Answer Posted / hardik085

because churning will come and hp exhaust temperature will go high

Is This Answer Correct ?    12 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the meaning of SST300 V56A in SIEMENS turbine

4355


By any way can we increase the B check hours from 300 to 500

2192


What is difference between secondary Air & Tertiary Air and Their use.?

2003


how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?

1694


LAPT working in alternator / generator

3620


What is LB-SR.

2999


Why superheated are started before I'd and rd fan?

2179


How to calculate power press toneage

2057


How do you consider that you can improve and what assistance do you need to achieve this

1756


what is the trip circuit supervision in an electrical meaning?

2118


DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.

1002


our 125 kva DG does not start in AUTO mode works normally in MANUAL mode please give me a solution.....

1702


im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much

2000


why airtel use + 24 volts and other operators use -48 volt

2628


Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon

2477