Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why 1800 ml of dissolution media used In Carbamazepine ER USP
Tablets But other drug only 900 ml Media Used ?



Why 1800 ml of dissolution media used In Carbamazepine ER USP Tablets But other drug only 900 ml M..

Answer / rachitbana

Because during dissolution development of Carbamazepine ER tab Complete drug release was not achieved in 900ml media for 400 mg strength. Thus 1800 ml volume was selected.

-Rachit Bana (Scientist- Torrent Pharmaceuticals )

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why using Potentometry What Purpose? differance between manual and potentiometry? why using Some of materials in usig potentiometry? What is use of mericuric acetate in Potentiometry

1 Answers   Biocon,


for which product require to do content uniformity? what is limit of cu?

0 Answers  


what r the parts calibrated in gc

21 Answers   ELBS, Reddy Labs,


what is role of pH in mobile phase

3 Answers   Cipla, Dhanuka Laboratories,


how to get accurate result for Residue on evaporation in purified water

0 Answers  


what is the difference between Hydrochloric Acid & Hydrogen chloride

3 Answers  


why we use prednisone tablet in chemical callibration of dissolution apparatus?

6 Answers   Cipla, Mylan, Umedica Laboratories,


Why using 0.5% acetone in methanol mobile phase for HPLC Gradient performance check.

2 Answers   DRL,


Which buffer is used for LC/MS mobile phase & at What Conc.

3 Answers  


What is shaking level in GC?

0 Answers  


1 % solution is equal to how much ppm

32 Answers  


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

0 Answers   Hetero,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)