Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why 1800 ml of dissolution media used In Carbamazepine ER USP
Tablets But other drug only 900 ml Media Used ?



Why 1800 ml of dissolution media used In Carbamazepine ER USP Tablets But other drug only 900 ml M..

Answer / rachitbana

Because during dissolution development of Carbamazepine ER tab Complete drug release was not achieved in 900ml media for 400 mg strength. Thus 1800 ml volume was selected.

-Rachit Bana (Scientist- Torrent Pharmaceuticals )

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why the sucrose used in calibration of polarimeter

5 Answers   Neuland,


What is the difference between chiral cel OD-H & OD-RH ?

3 Answers   Aptuit Laurus,


In Number of Theoretical Plates (N) = 16 (tr/w)2. where tr: retention time, and W: peak width. My Question is here in formula what is 16.Can u explain briefly? ---Veerabhadrarao.M

3 Answers   Micro Labs, Richter Themis, Sun Pharma,


1.What is the difference between method validation and method verification 2.Which guidelines proposed to method transfer

0 Answers   Granules,


Related substance method equivalency on control sample or spiked sample?

0 Answers  


why we use caffeine for hplc calibration?

5 Answers   Aurobindo,


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

0 Answers   ABC,


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

0 Answers  


What is stray light in uv what are units for stray light

0 Answers   Dr Reddys,


Is there any difference in principal of reverse phase and normal phase chromatography? and why? Please update. Thank and regard

3 Answers   MSN Pharma,


why the same column give different retention time in hplc?

7 Answers  


Why the same type of columns showing different RT for a single product?

6 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)