what is the actual productivity of carpentor,fitter,masson
for brickwork and masson for plaster etc
Answers were Sorted based on User's Feedback
Answer / thiyaneshwaran shanmugam
1) 1 Carpenter + 1 Helper - 5.5 - 6.5 Sqm/Day
2) 1 Steel fitter + 1 Helper - 150 - 200 Kgs/Day (Cut, Bend, Placing)
3) 1 Maon + 1 Helper - 10 Sqm/Day (Blockwork)
4) 1 Mason + 1 Helper - 12 Sqm/Day(wall plastering)
5) 1 Mason + 1 Helper - 10 sqm/Day(Ceiling Plastering)
6) 1 Mason + 1 Helper - 8 Sqm/Day(External Plastering)
7) 1 Tiler + 1 Helper
12 Sqm/Day (Vitrified Tile)
10 Sqm/Day ( Ceramic floor Tile)
8 Sqm/Day ( Ceramic wall Tile)
| Is This Answer Correct ? | 105 Yes | 3 No |
Answer / pradeep muley
1 fitter with 1 helper - 100 kg per day cutting, bending & placing,
Mason - 100 to 150 Sqft per day
| Is This Answer Correct ? | 98 Yes | 25 No |
Answer / hari
1) 1m+1mh=10m2 blockwork per day
2)1m+1mh shuttering=around 5m2 per day
3)1m+1mh barbending=around 200kgs per day , inc cutting,bending,placing.
| Is This Answer Correct ? | 13 Yes | 4 No |
Answer / n.v.ramana
1)CARPENTER=150SQFT.
2)FITTER=250KG/DAY
3)MASON=300BRICKS OR 1CUM
4)MASON-PLASTER=200SQ.FT/DAY.
| Is This Answer Correct ? | 33 Yes | 55 No |
why do you desire to change from your current position?
how to conversation of all construction material in to brass
what is superelevation?
How to estimate quantity of paint in 1M3
How many types of rcc slab
how would you describe yourself and your ideal job
What is the density of 1:1.5 (Cement:sand) ratio in plaster? And Conversion in 12.5 mm thickness per square meter? Howmany Kg of Cement square meter in ratio of 1:1.5?
how to convert feet value in meter value?
Trapezoidal footing length = 2m , B=1.7m D=0.5m and d- 0.15m. Can anybody help and calculate quantity of concrete by explaining all formulas involved.
19 Answers DNA Infrastructure, HCC, L&T,
What is difference between MS and Tor steel ?? Please ellobrate...or state its charactersitcs??
4 Answers CLG, Indiabulls, TOR,
how many labour is required for 1cum of concrete?
The ff slab casted its thickness 100mm.2nd floor slab will be casting its 300 mm.how we shall be given suppot to that 300mm thk slab.ple way me
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)