how can change 12mmdia@150c/c bar spacing to 16mmdia
Answers were Sorted based on User's Feedback
Answer / vinod kumar, sriharikota
Dia of known bar d1=12 mm
spacing of known bar s1=150mm
d2=16mm , s2= ?
d1^2 / s1 = d2^2 /s2
s2 = (d2^2 x s1)/ (d1^2)
spacing of 16 mm bar =266.666 mm
| Is This Answer Correct ? | 434 Yes | 64 No |
Answer / sunil1505
dia 12 - 150
if 16 mm - 16*150/12
but after taking that spacing we should calculate the area
of steel in concrete..we should match the area of steel in
12 mm = area of steel 16 mm in that structure.
| Is This Answer Correct ? | 72 Yes | 38 No |
Answer / lohit havalagi
very simple when we increase the diameter of the reinforcing bar it results in increased area, so INCREASE the spacing to get the required area of steel.
| Is This Answer Correct ? | 39 Yes | 20 No |
Answer / mustafa mohd layeak
Consider 1m strip of slab.
Using 12mm dia bar with a spacing of 150mm,we get
Area of steel=754sqmm/m length.
So if using 16mm dia bar we get a new spacing
s=[(1000*201)/754].therefore new spacing
s=266 mmc/c. therefore use 16mm dia bar@250mmc/c.
But check [M/V + L']>dev length at support.
| Is This Answer Correct ? | 26 Yes | 11 No |
Answer / vijay
We can change the 12mm dia @150mm c/c spacing to 16mm dia @
150mm c/c but area of steel provided will get increased.
| Is This Answer Correct ? | 22 Yes | 8 No |
Answer / er.pramod k saroj
before D1=12 and s1=150 so change dia = D2=16. and spacing =S2= ? solve = S1xD2/D1. 150x16=2400/12=200mm. ans= 200 mm
| Is This Answer Correct ? | 27 Yes | 13 No |
Answer / daniel lemma
Let assume for 1m (1000mm) span
d1=12mm
s1=150 approx No. =8pcs
d2=16mm
s1=? approx No. =?
We have to use this formula
d1^2 / s1 = d2^2 /s2 So s2=266.66 and
approx Spacing 250mm, and
New approx No of bar will be 4pcs
| Is This Answer Correct ? | 13 Yes | 2 No |
Answer / kunal chandra singh
We can calculate the weight of 12 mm rebar in 1 sq m area with 150 mm spacing after that we can calculate by compairing 16 mm dia with calculated weight per sq m area to calculate unknown spacing .
| Is This Answer Correct ? | 7 Yes | 2 No |
Answer / er. ritesh singh
Suppose d1-12 mm bar & d2-16mm bar than area of d2*150 /area of d2 bar
| Is This Answer Correct ? | 9 Yes | 6 No |
why reinforcement is not provided at centre for beams r column
If i buy some material and the seller asks me my TIN number what does that mean?? Is it my Taxpayers Identification number or it is my Tax invoice number? What does both of these stands for???
The minimum compressive strength of 1st and 2nd class bricks
sir I got selected in rail vikas nigam limited and they call for interview but i don't what they will ask in interview please guide me if you have any experience
0 Answers L&T, Rail Vikas Nigam Limited RVNL, RRB,
What is meant by Characteristic Strength of concrete/concretemix and how is it related to the 28 day cube strength. Are these defined in either or both B ritish Standards or Eurocodes?
what is MIS (related to planning tools)
How Can Calculate Plastering Quantities For 260.04 square meter by using CM 1:4 with 25mm Thick ?
what is super elevation?
what is tacheometry?
How can we cross check the excavation and backfilling quantities.
what is SHEAR WALL ? why and where it is provided.
what is pH value of sewage&water.if pH value is given then how to calculate H+.
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)