Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how can change 12mmdia@150c/c bar spacing to 16mmdia

Answer Posted / daniel lemma

Let assume for 1m (1000mm) span
d1=12mm
s1=150 approx No. =8pcs

d2=16mm
s1=? approx No. =?
We have to use this formula
d1^2 / s1 = d2^2 /s2 So s2=266.66 and
approx Spacing 250mm, and
New approx No of bar will be 4pcs

Is This Answer Correct ?    13 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How many are the types of joints?

1207


What is the wall thickness of NP-3&NP-4 hume pipe as per I.S code

2147


What is difference between combin footing & rapt footing

1942


Cut Linten (RCC-1:2:4)on 10" wall - what should be the width and hight of cut Linten? Secondly, 1 X 1.6 foot,4" thick window sun/rain shed (Chajja)should consume steel,Cement, sand and Stone chips?

2544


how can can column be corrected when the design is not safe ? is the increasing the clearcover a solution?

1631


WET BULB TEMPERATURE AND DRY BULB TEMPERATURE?

2375


What are the problems one might face while having a Cantilever balcony?

1556


Why Is Propping Required For Long Structures Once The Form Work Is Removed?

1286


What is the difference between Grade I, II and III of GSB?

2668


Sir, Iam Applied in rrb for the posts of Junior Engineer.I want to know about the or question previews to study well.Pl send it to shukla_varun1985@yahoo.com.

2176


Hi how r u ? hope you are fine there . Please can u tell me tha Design life of Buildings as Per ACI CODE 318-99. It will be a pleasure for me .Thanks in advance

2549


how much percent are used 20mm,10mm?

1973


how to find out hard strata in bored pile when the DMC method adopted.

6084


a butt weld is specified by

3050


in staad pro. modelling for a parallel scissors chord truss, when i assigned roller support i.e fixwd but with all Fx, FZ, Mx, My and Mz release except Fy... the analysis results " in stability at a joint, with direction Mx or My..what could be the reason...anyone please explaing

3889