how can change 12mmdia@150c/c bar spacing to 16mmdia
Answer Posted / daniel lemma
Let assume for 1m (1000mm) span
d1=12mm
s1=150 approx No. =8pcs
d2=16mm
s1=? approx No. =?
We have to use this formula
d1^2 / s1 = d2^2 /s2 So s2=266.66 and
approx Spacing 250mm, and
New approx No of bar will be 4pcs
| Is This Answer Correct ? | 13 Yes | 2 No |
Post New Answer View All Answers
WHAT IS YOUR CURRENT SALARY
How to improve the strength of fly ash bricks to avoid corner damge? How to get the color lighter similar to normal concrete blocks/
what is the types of surveying?which type of survey carrying for type of work?
Any strength is a stress but any stress is not strength
What happens when water mixed with cowdung is used for priming instead of water for lifting water in pumps?
Tell me about triple point of water.
Design a shear wall of length 4.20 m and thickness of 250mm subjected to the following forces.Assume Fck = 25Mpa and Fy = 415Mpa and the wall is a high wall with central part 3440mm x 250mm and two 380mm x 760mm strong bands at each end with following loading. S.No. Loading Axial force Moment Shear 1 DL+LL 1950 600 20 2 Seismic load 250 4800 700