how can change 12mmdia@150c/c bar spacing to 16mmdia
Answer Posted / mustafa mohd layeak
Consider 1m strip of slab.
Using 12mm dia bar with a spacing of 150mm,we get
Area of steel=754sqmm/m length.
So if using 16mm dia bar we get a new spacing
s=[(1000*201)/754].therefore new spacing
s=266 mmc/c. therefore use 16mm dia bar@250mmc/c.
But check [M/V + L']>dev length at support.
| Is This Answer Correct ? | 26 Yes | 11 No |
Post New Answer View All Answers
What are the common ways of demolition?
a concrete mix 1 2 4 by volume with water cement ratio as .6 by weight if moisture content in F.A is 6% with 20% BULKING AND IN C.A 1.5% by volume. find quantities of different materials required for one bag of cement
Which is the direction of negative angle?
what is civil enginnering & what you need of this course?
If a slab concrete is placed with M-20 grade concrete, actually it has to be placed with M-30. what are the rectifications / measures to be taken after concreting is done.
what is spacing of wallar support of 3m column. the thickness of column is 0.25 m.
How do we calculate absolute pressure?
I have to conduct load test on greting cover, pressure gauge is in kg cm2, how to caluculate load on this greting cover.
Describe the advantages and disadvantages of using plastic and timber fenders?
What is the meaning of Brick- M 35 grade? Is it a common brick or it's a concrete brick?
what is anchorage length,lap length and (dont remember the last one)
how much cement and sand required for 1cum rr masonry
Which code is used for tor & tmt steel bar?
What is type failure of road surface? how to repair the failure of road surface?
Why was the empire state building made of steel?