How much binding wire is required for one tone reinforcement ?
Answers were Sorted based on User's Feedback
Answer / harathi nitin
As per Joglaker (Quantity Surveyor Book) it is mentioned as
for every quintal of steel reinforcement ( 1 quintal =
100kg) 0.9 to 1.3kg of binding wire is required
for 100kg of steel reinforcement = 0.9 to 1.3kg of binding
wire
for 1 tonne (1000kg) = 9 to 13kg binding wire will be
required
| Is This Answer Correct ? | 168 Yes | 19 No |
Answer / a.ramachandran
approximate 8kg, it is based upon thumb rule.
| Is This Answer Correct ? | 81 Yes | 36 No |
Answer / pradipkrdeb
It should be 5 Kg to 6 Kg for one tone reinforcement.
| Is This Answer Correct ? | 115 Yes | 84 No |
Answer / siva
Upto 16mm dia = 6.90/7.20kgs
20mm to 32mm = 8.00/8.30kgs
| Is This Answer Correct ? | 52 Yes | 24 No |
Answer / t.chandrasekar
10 kg of binding wire is normally required for tying 1tonne
of reinforcement rods
| Is This Answer Correct ? | 43 Yes | 20 No |
Answer / srinu.s
Genearly used for binding wire for 1tone
up to 8mm to 10 mm steel = 5kg/tone
12 mm to 16 mm steel= 6.5 to 7.65 kg/tone
20mm to 32 mm steel= 8.2 to 9.85 kg/tone
| Is This Answer Correct ? | 31 Yes | 12 No |
Answer / jitendra
it depends on reinforcement work and gague of binding wire,
for overall calculation 12 kg consumed for Residential
building .steel binding wire
| Is This Answer Correct ? | 34 Yes | 18 No |
Answer / surendra pal singh
one tone reinforcement required binding wire 10kg to 13kg
Note- depend on rcc strecture residential & commercial.
| Is This Answer Correct ? | 19 Yes | 3 No |
sir what is the mean of WBM
How to calculate the Qty of Mortar in 1 m3 Brick work? Detailed Calculation Required?
which Indian standerd code is used for billing
4 Answers Desai Construction, DLF, NKG Infrastructure,
what is assumption consumption of steel per m3 for raft
Explain the different types of building contracts?
If density of cement is 1500 Kg/m3, the how is specific gravity 3.15 ? (Density of water is 1000 Kg/m3)
What is the procedure of Waterproofing in toilet sunken area ?
why we used shahabad stone (ladi) in box type water proofing.what is the main roll of shahabad stone?
how do understand the plinth beam croos section diagram
What is the difference between BC and SDBC
Suggest how many column, beem, etc required for 30 mtrs x 21 mtrs width x 8mtrs height for industrial shed of ground floor. I want to know the quantity of tmt steel consumption and Concrete consumption for budgeting
0 Answers Vishal Pipeline And Engineering,
What should be the PH value of water for irrigation purpose
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)