how we identify between current transformer and potential transformer without having it name plate?
5 12816How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?
2148A group of machines (wind turbines) connected with 33KV feeder and each machines are having individual VCB. The 33KV feeder connected with 110KV/33KV substation. The 33KV feeder tripped by over current at Substation and fault recorded at Substation as OC-R&Y phase. Same time the group of machines VCB tripped by over voltage, the fault recorded voltage was above 66KV by numerical Under/Over voltage relay. While grid drop time, this much of voltage hike is possible?
1 3414I have running 4 generator in paralel.All generators Voltages is same(470 V),KW also same (100 KW) but only No2 generator Amper is high than another generators. DG No:1,3,4 470V,100KW, 150 A DG No:2 470V,100KW,400 A
4 5603Post New Electrical Engineering Questions
what are the industrail measures to over ferranti effect? how would the ferranti effect the power system if those remedial mearsure arent taken? how often does this effect occurs in real power system?
What is mean 2XWY
How much depth n width required for laying of 1X70 Sqmm Cable in Desert???
1.What is the range of stator resistance of 3-phase induction motor? 2.Two electrically operated vibro motors are foxed in parallel direction in vibrating feeders. what is the direction of both vibro motors?
What are the weight of 800KV DA,DB and DC type tower ?
how many types are their in switchyard or substation(like D,I TYPE), what is differant between them
Draw torque - speed curve and load curve of induction motor? mark operating point ?
Is it possible to use a S1 duty class motor for crane application (S4)? If not, why?
what is an unbalance in acircuit? in a three phase 3wire circuit how an unbalance will come? in a three phase four wire system how an un balance is coming?
At the starting of dc motor and syn.motor and induction motor high current flowing through the winding. Due to this the windings burnt out. To avoid this different types of starters are used. But incase of transformer what Will be used (At starting no emf is induced in the primary winding)?
Witch do depand of Power factor and theory of power factor?
What is BusBar integrity test and how it is conducted?
what is difference between isolation and ultra isolation transformer?, what is the method of testing ?
what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable
what are the advantage and dis-advantage of 3 phase 4 wire energy meter?