Electrical Engineering Interview Questions
Questions Answers Views Company eMail

what is the max working temperature of an oil filled transformer say of about 1500kva.

3 12130

oil sample dielectric test gives the insulation rupture voltage at 26 kv. is this transformer safe to be operated . The working voltage is 11 kv

2 3682

We have one 500KVA transformer. We have tested REF relay and commissioned. After one and half year, due to some ground fault in one of the DB circuit Transformer tripped by REF relay. What will be cause and remedy. Please advise?

1 4709

formula for incomer breaker size calculation of powerfactor correction unit

3 17522

lightning current is ac or dc..?????

7 7757

HARMONICS ARE ALWAYS IN INTEGER LIKE 2ND OR 3RD HARMONICS,NOT IN FRACTION LIKE 0.5 HARMONICS.....????????

2 3561

what is resonance in electrical circuit and its effect? where we get high resonance and low resonance?

1 2586

what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?

HAL,

1998

what is reactive power (MVAR) and how it is control? how it is generate in powerplant?

1 14486

how to maintain standard votage in power system?

5 5668

What is auto reclose system in Circuit breakers??

4 19309

what is the general Classification of Generators

2 12063

E.B sending end to receiving end 33kv ug cable laid 8Km,receiving end to ss1,ss2,ss3,ss4 all are Approx 800 Mtr,can go for 33KV to 430V or 33kv to 11kv in receiving end and 11kv to 430 near ss ,which one is good for technically and economically.

JLL,

1 3476

which motor is used in watch..??????

Bhushan ITI,

3 22403

what kelvin's law ?

1610


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

please send me jindal previous aptitude and technical question and answer.my email id is deep_raj@live.com

1503


As we know diode work on both negative and positive but converting ac into DC we have to given a/c from negative of diode or positive side.please give me answer.

1172


HOW WE CAN REDUCE THE CIRCUIT COMPLEX OF STAR-DELTA STARTER .BECAUSE NOW WE USING ONE TIMER RELAY & THREE CONTACTOR FOR MAIN,STAR & DELTA ?IF ANY IDEAS PLZ POST.THANK U

2006


what is kvarh? Please define it With calculation General motors ?

706


How to design pavement quality concrete by using C.R.C.P Method

1290






What is the maximum operating temperature for a thermoplastic insulated cable?

659


where the lexical paramater will use in fron end?

1451


What is the difference between hot and cold loop testing?

676


what are the analog quality input for protection function?what are minimum reqiments?

1419


If Neutral Grounding Resistor (GR) failed/shorted. Is it repairable.

1157


In Indian Household, generally we receive 220V AC single phase supply. But AC has 2 phases, +ve & -ve. So in +ve half cycle current is flowing...so what happens in the -ve half cycle?? Please illustrate.

1600


why does the magnetic balance tests at transformer?

1429


use of PIR in ehv breaker

1717


If short circuit ratio is high is it bad or good for a machine then tell the reason...

1607


why swinburnes test cannot be performed on series machines?explain

1840