Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

2 6326

WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?

ABB, Nissi Engineering Solution, NSL Sugars,

5 25660

what is the function of CRGO in a Transformer?

6 11269

what happens when a DC supply is given to AC motor?

Areva, ISMT,

9 24875

what is the difference between elcb,rccb,mcb.

HCL, RCCB,

8 41876

I have a shop heater with a 1/3 hp capacitor start, induction motor driving the fan. Intermittently, the fan motor speeds up significantly for several seconds (15-60 sec) then slows to normal operating speed. The manufacturer suggested changing the capacitor which made no sense, but I did it to no avail. Could this possibly be caused by the centrifugal switch intermittently reconnecting the start winding?

1 3717

how we masure a cuurrent?

5 7070

when we increased the current what do ?

2025

how we calculate the dick for a pole?

Power Grid,

2145

name the types of insulatter?

5 8574

what is the principal of star delta starter?

9 46681

HOW TO BUILD THE SINGLE PHASE TO THREE PHASE CONVERTER? CAN PROVIDE ME CIRCUIT..THANKS

2081

I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.

Jindal,

2236

Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?

Accenture,

2011

How to calculate the current rating of power cables ?

1 6463


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Single line digram for 11 kV to distribution use go,la and do

1769


What are the internal and external faults?

1052


What is the RMS and DFT principle of analogue maesurments. Which way they are advangages. where which princples give optimum results.

2628


What is EHT tariff or Power factor Tariff ????

2309


How to size fuse? How to size MCB?

1471


Between educational qualification and practical work experience, give us a brief explanation on your practical experience in your past Endeavour that you performed well to the satisfaction of your past or present employer?

2217


How to select the earthing transformer,for DELTA TO DELTA TRANSFORMER OR ALTERNATOR SIDE.Pls post your answers and calculation.

2332


How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?

1936


What is the difference between security constraint unit commitment and security constraint optimal power flow?

1672


How to reduce -234126219.6403 MVAr generation and by what?

1590


How do I calculate a WTI CT ofa 1250kVA 6600/400V transformer

1715


A jet of fluid strikes a plate What was the force required to counter it?

1840


1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?

1823


WHAT IS MEANT BY DERATING OF THYRISTOR?

2913


what is per unit calculation?looking for simple and strong explanation thk u

2841