Why the tapping connections are taking above for gas service and below for liquid service?
ADCO,
2 6660We have a Yokogawa Micro-XL DCS, which is having around 300 I/O, but whenever there is any wire gets grounded in field, the 24v supply to all loops gets dipped & all the indications at DCS goes to IOP(shows input open), at present we have fixed 500mA fuses in all the lines but which does not working. Does it required to replace with lower amps fuse, then how much or is there any other solution for this.
2 6759How to calibrate RC Feeder system in thermal power station?,If any instrument available to calibrate it,ple inform me. make:stock,
TATA,
3175I have a MRE200 amplifier for controlling a mitsubishi servo motor, I would like to know how many pulses are required to rotate the servo motor by 1 degree and what must be the pulse width
1 5012I want to know if flowrate increases in 16' pipe line what will happen to upstream pressure and why?
1 3563In 16' pipeline one pcv is installed which is controlled by PT installed at inlet of PCV.If Flowrate in pipeline increases what will happen to pressure at the inlet of pcv.
5 11166how many pulses are required by a ac induction servo motor of 4 poles with 50 Hz frequency to rotate by 1 degree?
2112what is the relation between flow and pressure.for example relationship between level and pressure is p = phg like that i want ans for this question.and also how to calculate orifice sizing and flow transmitter. pls some one ans for this questions.
3 8967What should be the ideal tapping location for pressure differential transmitter for liquid service. If the tapping taken from the top of the pipe then PDIT will work properly or not. If PDIT do not work properly then what minimum corrective action should be taken in order to solve wrong tapping locations.
1 6955Post New Instrumentation Questions
while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?
what is maxdna ?. explain about the software details.
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?
HOW TO SOLVE PROBLEM WITH ENRAF LEVEL TRANSMITTER 854 ATG THAT PASSWARD DO NOT Exist INTO TRANSMITTER TO ADJUST LEVEL WITH PORTABLE PET 847, WRITTEN WRONG PASSWORD , I AM SURE THAT DEFAULT PASSWARD (W2=ENRAF2) IS THIS TRANSMITTER NEED TO REPLACE SOFTWARE AND HOW?
Conversions
Explain the working of an enraf level gauge.
Name different parts of a pressure gauge.
How u measure the massflow in orifice flow measurement techniques
this site is owned by an nonsense
what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?
WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN
where proximity sensor installed on tank in loading arm application
when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??
selection criteria of control valve? and selection criteria of actuator explain in brief?
Difference between dcs and plc including date processing and architecture.