Which pump set is more suitable and economical for
liftingwater from 300Mtr borewell?
A. Compressor Pump
B. Submersible Pump
C. Jet Pumps
D. 25HP Centrifugal Pump
Q. from PSC Test 22-11-2008 Meter reader
Answers were Sorted based on User's Feedback
Answer / h nayak
Hi friends,
Submersible Pump is suitable for lifting the water from 300
ffet depth.
| Is This Answer Correct ? | 7 Yes | 1 No |
Answer / puneet singla
submersible pumps are more suitable for lifting water these submersible have different models which is to be installed at the location also installations is depend upon the connections type and according to water needs. if there are 5acre of lad and connection is of 25hp than 25 hp 8 stage v8model is highly suitable which give 850 ltr approx a minute
| Is This Answer Correct ? | 2 Yes | 1 No |
Answer / raj
subersible pump & 25 HP centrifugal pump are more suitable
and economical for lifting water from 300 meter borewell.
| Is This Answer Correct ? | 5 Yes | 5 No |
Answer / sidhu.k
hi, above all the guys are given answers not fully
satishfied ,as per my knowledge see water lifting is depend
upon the capacity of the motor, and pump stages,15hp 28
stage submursible motor is sufficient for 300mtr depth
water lifting .i dont no purpect formula , but it is to be
allready done in my practical life. 1 stage = 35ft.ok,any
body have formula to caculate this please send
immidietely.thanks to all friends.
| Is This Answer Correct ? | 1 Yes | 2 No |
Answer / harikrishna
hi friend this is harikrishna from hyderabad
I think jet pump is suitable for lifting the water from 300
ffet depth.
| Is This Answer Correct ? | 3 Yes | 5 No |
Answer / ahmed
25 HP CENTRIFUGAL PUMP IS ECONOMICAL FOR LIFTING WATER OF
300Mtr BOREWELL.
| Is This Answer Correct ? | 1 Yes | 4 No |
In Swinburne's Test on D.C.machines, why the efficiency is more when the machine runs as generator than when it runs as motor???
6 Answers College School Exams Tests, GE, MVR, Practical Viva Questions,
what rectifiers is and what are the types of rectifiers?
Actually why the transformers are rated in KVA.?
how can we calculate that how much capacitor is needed for a system to increase the pf?
Name one of major transformer company in KSA ?
working principal of online ups
0 Answers Delta Power Systems,
what is the reason of power development in synchronous generator due to saliency ?
How to use a insulation resistance tester on a three phase electric motor?
sir, my question is that if we start any three phase induction motor with star connection.will be current taken ? please send a formula.
On what principle reluctance motors work?
what is F.A.P in fire alarming system?
what are the different functions of mccb, rccb / elccb ?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)