Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is differences between the Instrument and Equipment

Answers were Sorted based on User's Feedback



What is differences between the Instrument and Equipment..

Answer / b.gangatharan

We can not get results directly from equipment.but we can get results directly from instrument.
Thanks,,
B.gangatharan
Caplin point.

Is This Answer Correct ?    22 Yes 0 No

What is differences between the Instrument and Equipment..

Answer / kumarpharma

Yes,i agreed with Mr.gangatharan.equipment will not give analysed results directly.
Regards,
Kumar.s

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is polarity and how to calculate

2 Answers   Reddy Labs,


Why the same type of columns showing different RT for a single product?

6 Answers  


in api coa contains only process impurities and in product coa contains degradation impurities?

0 Answers  


what is SOP?How can prepare?

1 Answers   Reddy Labs,


in hplc calibration injector linearity pass,it means inj and det is good. why to perform detector linearity is it required, if it is required,what is difference between injector and detector linearity in hplc calibration

4 Answers   Dr Reddys, Hetero,


why 6 tablets use for dissolution

1 Answers   Cadila, IPCA, SUN, Teva Pharmaceuticals,


what are the different methods of analysing related substances test,what are LOD AND LOQ .HOW TO REPORT IMPURITIES WHEN LOD AND LOQ LIMITS R SPECIFIED

3 Answers   Dr Reddys,


what is the difference between the ordinary loss on drying technique and vacuum oven technique?

1 Answers   Divis Laboratories,


mahagenco syllabus for the post of chemist

0 Answers   MahaGenco, Unimarck Pharma,


In HPLC Chromatographic separation Resolution equation is Rs = 1.18 (tR2 –tR1)/wh1+Wh2, Where, tR2 and tR1 is run time of eluent ratios of the distances from the point of application to the centers of the spots and the distance travelled by the solvent front from the point of application (retardation factor), and Wh1and Wh2 , is peak width of at half height. What is 1.18 ?

1 Answers  


which effect is mainly responsible for chromatographic separation when silica is the statinary phase at TLC? thanks in advance

1 Answers  


i want to know about headspace and interview question on headspace

1 Answers   Srikem Laboratories,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)