Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


From where 16 or 5.545 is derived in theoretical plates
calculation formula by USP or JP/BP/DAB and what is meaning
of this coefficient and impact in calculation ?

Answers were Sorted based on User's Feedback



From where 16 or 5.545 is derived in theoretical plates calculation formula by USP or JP/BP/DAB an..

Answer / sp goswami

formula for N = 16*(t/w)2
but whats the meanin of 16 and from whr its coming ?

Is This Answer Correct ?    5 Yes 0 No

From where 16 or 5.545 is derived in theoretical plates calculation formula by USP or JP/BP/DAB an..

Answer / dr. sp goswami

it comes auto width algorithm, also by calc of plate
thickness and how many plates can be in imaginery plates
when width is measured at 13.4% of the height(USP),50%(JP)%
By tangent to the baseline so every time due difference in
percent height calc in USP,JP, BP,DAB,EMG and 5sigma,4
sigma ,3 sigma there will be different values for this
coefficient like 16(USP),5.545(jp) etc
regards

Is This Answer Correct ?    6 Yes 3 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the defferance between the potency and working standard

1 Answers   Arbro Pharmaceuticals, Caplin Point, ECOlogics, Matrix, Orchid, Venus Remedies,


what is primary solution and secondary solution

2 Answers  


How we develop a method by HPLC for unknown compound,if we got three peaks with same response then how we can find out which one is our desired compound's peak without taking help of LC MS.

4 Answers   Apotex, Kemwell,


why we are using polystyrene film for calibration of I.R spectroscopy?

12 Answers   Abbott, Andhra Organics, Intas, Kemwel, Reddy Labs, RRR, Veritas, Zydus Cadila,


what is the difference between the Purity and Potency of drug substance

1 Answers   Divis Laboratories, Graviti Pharmaceuticals,


Why we inject a standard 6 times for Related substances by HPLC and 5 times for Assay?

3 Answers   GVK,


HI,I CLEARED BOB CLERK EXAM. MY INTERVIEW WILL BE ON 9TH OCTOBER,2010.PLEASE SEND ME INTERVIEW QUESTIONS AND ANSWERS. THANK YOU.

0 Answers   Bank of Baroda,


iam usig ph buffers merk. manually how to prepare ?

0 Answers  


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

0 Answers   Orchid,


What is split ratio in Gc? Splitless? how requirr to select?

0 Answers  


What is stray light in uv what are units for stray light

0 Answers   Dr Reddys,


why we are used 4,7,9,2 buffers for the ph calibration

4 Answers   Aurobindo, Enaltec Labs,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)