Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why neutral has to switch on-off with phase in TN IT TT systems i.e neutral should be taken as fourth pole



Why neutral has to switch on-off with phase in TN IT TT systems i.e neutral should be taken as fourt..

Answer / k.prakashchandra

As a safety measure , the tr is completely isolated

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

what are the types used for alternator earthing,what will happen if more than two alternator is working in parallel with each having own system earthing.is there any possibility for circulating current in between two system.

3 Answers   BEL,


On Which Pressure PRV is operated.

0 Answers   AEPL,


i want wipro vlsi placement pattern please send me

0 Answers  


what happens if commutator is removed in an dc machine?

3 Answers  


why the power cut problems occur in tamil nadu? may i know the exact reason.plz

17 Answers  


We have three 33kv substations. All of them energised by same source.When i am checking the phase sequence between one substation to other substation (like R Phase to R Phase) by multimeter i am getting some voltage.Near to LT panels UPS panels are there. Can u explain whether any possible to happen like that. In Phase SEquencemeter is showing correctly in both substations. How is it happen. Explain me.Explain me communication signal will produce Phase difference on this case.

3 Answers  


brief notes on ammeters

0 Answers  


OUR METER READER TAKE READING OF INDUSTRIAL CONSUMER.THEY ALWAYS ASK HOW TO INCREASE POWER FACTOR FROM 60% TO 99 % TO AVOID PENALTY OF POWER FACTOR.

3 Answers  


what is the healthy specific gravity of lead acid battery used in DG sets ?

3 Answers   Bhushan Power Steel,


how much flux density of CRNO core

0 Answers  


can we run a motor rated 50Hz,415vac,1440RPM At higher speed then rated on name plate with the help of VFD /drive on long term basis.wheater it will effect the motor life

3 Answers  


how many test is necessary for 27mva transformer.

3 Answers   HEG,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)