Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is the meaning of Base deactivated vials



What is the meaning of Base deactivated vials..

Answer / b.gangatharan

Base deactivated vials have silanized surface to prevent adsorption of highly polar molecules.
Thanks,
B.Gangatharan,
Caplin point,
Puducherry.

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

0 Answers   GVK,


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

0 Answers  


please explian me about area normalisation method,diluted standard method,impurity vs impurity and which one has to be selected in method development

0 Answers   Pfizer,


why a ph meter require KCL solution for their storing condition?

1 Answers   Aurobindo,


how many types of Proceing methods?

8 Answers   Reddy Labs,


how to prepare 5 normality of h2so4 solution

3 Answers   Symbiotec,


how to pepare 6.8 pH phosphate buffer

10 Answers  


explain 5 components of gas chromatography ?

1 Answers   College School Exams Tests, Nucon,


What is similarity factor and its use in api strength?

0 Answers  


what is the basic principle of conductivity meter

4 Answers   Hetero,


what are peak purity,peak purity index,peak thresold

2 Answers  


If change in specification which parameter require to do for validation? if change in chromtographic condition then which parameter? if api change then which parameter? if change composition then which parameter? if old method not work out then whicj parameter? if additional one impurity added then which parameter of validation require to do on above each conditions? elaborate separately

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)