Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


My question about gas chromatography sulfur chemiluminsecence detector.
I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM .
I'd like to inform you that both GCs are calibrated and have very good
operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm
Best regards


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Analytical Chemistry Interview Questions

How you develop a method in HPLC?

0 Answers   CU, Perrigo, Wockhardt,


What is the exact reason to use THF and IPA in buffers of Reverse phase HPLC as a solvent?

1 Answers   Dr Reddys,


Why triethylamine and o-phosphoric acid used while setting pH of mobile phase during HPLC Analysis?

6 Answers   Hapten Healthcare, Pharmaceutical,


What are the different zones in stability according to ICH?

1 Answers   Apotex,


sop of a uv visible spectrophotometer double beam elico model

0 Answers   Sun Pharma,


difference between pH & pOH ?

4 Answers  


If we have a kc is1*10^8 and the .kp 2*10^5 of reaction A------->B C------->D what is the volume of C?

0 Answers  


Which are the diffrent grades of api in pharma?

0 Answers  


What is difference between known and unknown impurities

1 Answers   Sun Pharma,


What is control room temperature and which guide line says?

0 Answers  


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

0 Answers  


WHAT IS THE USAGE OF REFRACTIVE INDEX IN PHARME FIELD

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)