Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


My question about gas chromatography sulfur chemiluminsecence detector.
I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM .
I'd like to inform you that both GCs are calibrated and have very good
operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm
Best regards


No Answer is Posted For this Question
Be the First to Post Answer

Post New Answer

More Analytical Chemistry Interview Questions

What is the principle of Thermal conductivity detector and FID?

0 Answers   Cipla,


In HPLC (Waters) software Empower1,2 &3 what is the updation for each version

0 Answers   APL,


what is pKa ?

10 Answers   Dr Reddys, Shasun Chemicals,


Why red HgI2 added during starch preparation?

1 Answers   Aurobindo,


In dissolution of tablets/capsules elaborate the Dissolution limit 20.0% to 60% Q in 30 minutes.

1 Answers  


what is the difference between BDS and ODS Columens and both are same or not

2 Answers   Intas, IPQA, Micro Labs, Vasava Engineering Private Limited,


why we are using sodium,potassium phosphates for mobile phase preparation?

1 Answers  


how to pepare 6.8 pH phosphate buffer

10 Answers  


how much mass should be there in volumetric flask while in preparation of sample for assay? 

0 Answers   Reddy Labs,


why equlirium conatant of water have 14 value

1 Answers   GVK Biosciences,


why we use holmiumperchlorate in calibrating uv

4 Answers   Aurobindo, DRL, MSN Pharma,


IN DISSOLUTION TEST S1AND S2 AND S3 CONDITIONS ALL ARE FAILED THEN WHAT IS THE DESSICION U CAN TAKE

12 Answers   Cipla,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)