Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why we are taking 89ml concentrated HCL for preparing 1N HCL

Answers were Sorted based on User's Feedback



why we are taking 89ml concentrated HCL for preparing 1N HCL..

Answer / jyoti temkar

Actual strength of commercial HCl is 36%.
Molecular wt of HCl is 36.5
Density is 1.18 g/ml
So wt of HCl for 1 M is 36.5/(36/100) for 1000 ml
As volume = mass/ density,
Volume of HCl for 1M Strength in 1000 ml will be
36.5*100/(36*1.18)
=89 ml

Is This Answer Correct ?    19 Yes 4 No

why we are taking 89ml concentrated HCL for preparing 1N HCL..

Answer / abcd

since we r using fuming hcl ,so that the strength of the acid decrease while open it to atmosphere, so that we take 89 ml instead of 85 ml.

Is This Answer Correct ?    1 Yes 0 No

why we are taking 89ml concentrated HCL for preparing 1N HCL..

Answer / abcd

since we r using fuming HCl , so that the strength of the acid decreases if we kept open the acid to atmosphere ,so that we take 89 ml instead of 85 ml.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why disodium tartarate is used for autotitrator calibration

2 Answers   Cipla, Micro Labs,


Difference Between End Cap HPLC Column and Non End Cap Column

2 Answers  


In HPLC when we use Isocratic method, Gradient method in hplc?

8 Answers   Pharmaceutical,


why in GC calibration of linearity regression coefficient should not be less than 0.999

1 Answers   Acacia, Jubilant,


Why we are use 0.005M Sulphuric acid, in control of absorbance performance test UV Spectrophotometer calibration

2 Answers   Cipla, Reddy Labs,


why we can use only 4 and 7 and 9 buffers in pH calibration

1 Answers   Chola, Cipla,


why wetlab is called as wetlab

6 Answers  


how a particular wavelength can be different for a particular compund while analysing by uv and by HPLC.

0 Answers  


How we fix the validity period of a Normal solution and re-standardization due date

3 Answers  


What is principle of Polarimeter?

21 Answers   Intas,


what is the method of UV cabinet CALIBRTION

2 Answers  


how to prepare 25 ppm acetone. explian with formula

4 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)