Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we are taking 89ml concentrated HCL for preparing 1N HCL

Answer Posted / abcd

since we r using fuming hcl ,so that the strength of the acid decrease while open it to atmosphere, so that we take 89 ml instead of 85 ml.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to do regeneration of Metacarb Pb plus column?

2580


What is the use of tlc and hplc? And when and where use?

1157


EXPLAIN THE CALCULATION PART OF AN KF TITRATOR CALIBRATION WITH SUITABLE EXAMPLE

2636


why we should take dst factor for below 1%moisture samples

2666


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3486


Home heating oil or furnace oil what is made from? Can (base oil plus diesel/kerosen) = home heating oil?

2184


I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


How to know the estimated LOQ concentration in ppm

1213


in stress study if your api not soluble in hcl naoh h2o2 then what require to do?

836


Which parameter require to do for analytical method equivalency?

776


What is diffrence between extractable volume and deliverable volume? Answer pls

4573


Why a1% value is used for some product ? What is the criteria for selection a1% value ?

2346


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3178


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

771


in each media we require to use SLS? how to proceed?

787