Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why do we use around only 60 mg of K2cr2o7 in the UV
calibration -control of absorbance test?

Answers were Sorted based on User's Feedback



why do we use around only 60 mg of K2cr2o7 in the UV calibration -control of absorbance test?..

Answer / kishor solanke

Because this resulting solution gives absorance in the
range between 0.2 to 0.9 absobance which is the optimum
range of absorbance for UV-spectrophotometer.

Is This Answer Correct ?    21 Yes 1 No

why do we use around only 60 mg of K2cr2o7 in the UV calibration -control of absorbance test?..

Answer / vishu

K2cr2o7 cover both uv and visibale range therefore use for calibration

Is This Answer Correct ?    3 Yes 2 No

why do we use around only 60 mg of K2cr2o7 in the UV calibration -control of absorbance test?..

Answer / ravindra m

Eventhough it is a colour solution, it is a wide rage of spectrum in UV region.

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is difirence b/w ROI&ROE

1 Answers   Pfizer,


is a bonded water molecule in an organic material can be easlisy and accuractly determined by KF rather than LOD

2 Answers  


please explain about aluminium hydroxide assay

0 Answers  


What id the resolution factor

1 Answers  


In HPLC (Waters) software Empower1,2 &3 what is the updation for each version

0 Answers   APL,


what is the moisture content of Disodium hydrogen tartrate. how it can be calculted. as 16.5%

1 Answers  


gc Calibration % RSD failed what is the possible reasons?

5 Answers   Divis Laboratories,


why require to do water content for drug product?

0 Answers  


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

0 Answers   NCL,


what is mean by content uniformity?

5 Answers  


what is diffrence between Specific optical rotation, optical rotation?

3 Answers  


Which water can use Hplc analysis

9 Answers   BioGenomics, Dr Reddys, Reddy Labs,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)