WHAT IS A SYMPTOM OF FAULT WITH THE SPAN OF AN INSTRUMENT?
1)ZERO-POINT AND 100% ARE CORRECT BUT NOT A MID-RANGE.
2)ZERO-POINT IS CORRECT ,BUT 1005 INPUT IS NOT GIVING 100%
OUTPUT.
3)LINEARITY PRBS.
4)1005 O/p IS CORRECT BUT ZEO POINT IS WRONG.
Answer / carl_ellis
WHAT IS A SYMPTOM OF FAULT WITH THE SPAN OF AN INSTRUMENT?
1)ZERO-POINT AND 100% ARE CORRECT BUT NOT A MID-RANGE.
2)ZERO-POINT IS CORRECT ,BUT 1005 INPUT IS NOT GIVING 100%
OUTPUT. 3)LINEARITY PRBS. 4)1005 O/p IS CORRECT BUT ZEO
POINT IS WRONG.
The correct answer is 2, but number 4 also requires a span
correction.
1) The "Zero-point and 100% are correct, but not a
mid-range value" problem is a linearity problem.
2) The "Zero-point is correct, but 100% input is not giving
100% output" is a span problem.
4) The "100% output is correct but zero point is wrong" is
a zero offset AND a span problem because when the zero point
is corrected with the addition of a bias/offset, the 100%
point will shift up or down the same amount as the zero
shifted with the bias/offset correction. So the 100% point
will no longer be correct once the zero is corrected.
Hence, the zero AND the span will need to be corrected.
Carl Ellis
Measure First
| Is This Answer Correct ? | 8 Yes | 2 No |
What is the difference between intrinsic instruments and ATEX instruments?
CAN YOU USE MOVING COIL METER FOR MEASURING A.C?
describe flow nozzel principle?
What is motion balance principle?
Explain about safety integrated level protection? . How it was differ from other protections ?
what is Least Value of MICROMETER?
To calculate temperature, why we multiply 25 with mV?
What is the meaning of slope in PH transmeter?
What is the meaning of wet leg
Ple give me "INDUSTRIAL INSTRUMENTATION AND CONTROL S.k. Singh 3th edition" Solution manual to self-Check Quiz and chapter-wise PowerPoint Slides. Home web-site not available... Ple Ple Ple Ple Ple Ple Ple Ple Ple Ple Ple Ple Ple Ple Ple Thanks for all...
Calibration of controller (pneumatic)
Can you tell me how we will select RTD and Thermocouples for Temperature applications. I.e How we will choose accurate one for a specefic operation if both having same ranges
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)