Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


difference between vaccum pump and ejector

Answers were Sorted based on User's Feedback



difference between vaccum pump and ejector..

Answer / tsunami

1.the only difference between them is ejector uses auxiliary
steam to remove the air from the condenser and the pump uses
water to remove the air by rotating the impellor that causes
suction of air from condenser.

Is This Answer Correct ?    31 Yes 2 No

difference between vaccum pump and ejector..

Answer / santosh

k. The main differec is that and also other difference is the ejector will produce more hogging during initially.

Is This Answer Correct ?    3 Yes 5 No

Post New Answer

More Power Plant Engineering Interview Questions

what is the meaning of SST300 V56A in SIEMENS turbine

0 Answers   Siemens,


How to calculate power press toneage

0 Answers  


what is need of primary water system in power plant?

1 Answers   JO, MPL,


if suppose boiler has high heavy tube leakage, so in which time we feed the water in a boiler. can we stop the feed water at particular combustion temperature.

4 Answers  


why prds line tapping taken from ms line as Pri SH O/L temp & pressure is sufficient to full fill our requirement of PRDS..

3 Answers   GIPCL, OEGI,


What is the use of NULL meter on AVR panel

5 Answers   Power Plant,


what does mean by kva rating

0 Answers  


what is turn down ratio

4 Answers  


what is actual CAL MODE & cal means?

2 Answers   GIPCL,


Due to the sensitive earth fault Our Power plant Get Tripped Several Times, It happens in the morning time daily, When temperature rises that means sun rises the earth fault current get lower, in this situation What should I do to get rid of this Problem?

2 Answers  


What is creep, resilience.

2 Answers  


What happens if air is present in LPH and HPH.

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)