Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why we use only six bowls for dissolution of a drug



why we use only six bowls for dissolution of a drug..

Answer / shailendra singh, shreya

The use of six dosage units as the basic sample size in
dissolution is partially due to the configuration of the
dissolution test assembly with six positions. However, in
some statistical procedures such as the estimation of a
confidence interval for precision of a measurement, a
sample size of six represents the point of diminishing
returns where the decrease in the confidence interval from
5 units is significantly greater than the decrease from 6
to 7 units. Thus the added value of obtaining additional
measurements is significantly less once six measurements
have been acquired.

Is This Answer Correct ?    14 Yes 15 No

Post New Answer

More Analytical Chemistry Interview Questions

control of resolution in calibration of IR

3 Answers  


why we are using 6 dosage units in dissolution, and why we are using 6 tablets in disintegation test.is there any scientific reason beyond 6?

1 Answers   ABC, Alembic, IPCA,


How can we detect a compound in hplc which does not have any chromofore?

1 Answers  


why IR graph or spectra comes down ? Any reason

4 Answers  


Why we are using a Kf Factor range 4 to 6

7 Answers  


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

0 Answers  


What is the column performance and column efficiency?

1 Answers   Reddy Labs,


What is impurities in pharma analysis?

1 Answers  


only one end point is possible for citric acid and we get 2 end points for di acid why?

3 Answers   Reddy Labs,


which solution used for detecting factor of k.f.titroter except water

3 Answers  


How to determine retention time in Chromatography

2 Answers   Mylan,


What is the definition of water content or moisture content,what is the procedure going on w.c amalysis?

1 Answers   Cipla, KIYI,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)