Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is the definition of water content or moisture
content,what is the procedure going on w.c amalysis?



What is the definition of water content or moisture content,what is the procedure going on w.c amal..

Answer / msj

In API synthesis using water as final purification steps,check the water content and in spec also will mention water content.but some of the api's usd solvents for purification purpose.these solvents pick up the moisture frm atmospear at purification time and some of apis having more hygroscopicity nature these two conditions will check moisture content.in spec will mentioned moisture content.water content and moisture content analysis is same.

Is This Answer Correct ?    10 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why we use deturium lamp in uv spctrophotometer other than lamps

1 Answers  


how PH an important role in HPLC separation

3 Answers  


why we use Dichlorobenzene.nitrobezine.t-butyldi sulhate.for calibration of gc Head space

0 Answers   Raks Pharma,


what is the significant of pH in HPlc?

5 Answers   Orchid,


What is AV value in test uniformity content ,describe calculation

1 Answers   Lupin,


1 why polyesterene film used for ftir calibration ? 2 why k2cr2o7 is used for control of abs in uv ? 3 why holmium oxide used for control of wavelength in uv

3 Answers  


What is colimn selection Criteria in HPLC analysis?

4 Answers  


How do u differentiate primary

1 Answers  


we calibrate HPLC once in 6 months while iam doing calibration i came to know that calibration was failed. then how can i justify that the samples analyzed on the system during this 6 months was wright? how can i forward in to the next step for those batches?

5 Answers  


A ha tc is actual defination of retention time?

0 Answers  


In my analysis by HPLC,In sample main peak and placebo peak are eluting with shorter resolution ( almost look like doublet). how can i get max resolution ? Is changing gradient method is usefull?

3 Answers  


How to calculate lamp energy in hplc?

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)