i m passed my engineering in 2010 in instrumentation and
control engineering. my question is can i apply for software
jobs or vacancies.??????????? plz give me answer soonnn......
Answers were Sorted based on User's Feedback
Answer / priya
s you can get the software jobs but its not suitable for
instrumentation field.. better you are trying
instrumentation related jobs
| Is This Answer Correct ? | 4 Yes | 0 No |
Answer / darsh
yes you can do if u hav knowledge thoroughly abt c or c++ or
dot net...do any one course and try to oncentrate on any one
surely u vl rock....coz ma frnd who studied ECE and placed
in patni software since she did dot net course...so you
havin chance to do and get
| Is This Answer Correct ? | 4 Yes | 1 No |
i hav applied for the post of engg. in iocl so please require the past test papers fro instrumentation engg please please help me and send me the papers or tell me the pattern and type of ques asked in examination......
How does milli volt is created in themocouple?
centrifugal compressor interlock? Tell me the parameter at which compressor will trip
Explain about safety integrated level protection? . How it was differ from other protections ?
hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q
What is an analog input-output
10 Answers TN, Torrent Pharma,
What is the difference between compensation and extension cable.
Where & Why we are using SURGE PROTECTION ?
What is the right procedure for adjusting the gap voltage of bently nevada vibration sensor?
How to change dcs card in online. (Dsc is maxdna)
SIR MAY I KNOW IF RADAR TYPE LEVEL TRANSMITTER SHOWING IN THE FIELD 0 % LEVEL AND IN DCS SHOWING 100% THEN WHAT IS THE CAUSE I CLEAN THE CHAMBER & TAKEN ONLINE BUT ONLY ONCE ITS BECOME ZERO IN DCS BUT AGAIN 100% SHOWING IN DCS,THEN I REMOVE THE POWER SUPLLY AND CONNECT IT AGAIN .IS IT OK BUT STILL IN THE DCS ITS 100% AND ON THE DISPLAY ITS INITILAZIATION PLEASE HELP ME READRING THIS?
my temperature transmitter in field showing 700 degree , whereas in dcs showing 459 degree, how to resolve this?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)