2102What is the correct procedure to shutdown VCB in 11kv substation.safety and work procedure
EGA,
3 18647I want to know what is the short circuit level when 8 NOS 2000 kVA, 415v, 50hZ generator connected in paraller
1 4369What will happen to the speed of synchronous machine subjected beyond the pull out torque? Are the behavior shown by rotor remains same for both the alternator and motor?
1 4206I find that underground strip-armoiured,4core,LT PVC cables in an earthed power distribution sytem are occasionly found in charred condition-with no trace of it except ash. Is this because of no proper earth connection/continuity (giving rising to high armour resistance)in the joint enroute or because of insufficient capability (again due to high armour resistance)of cable-armour to carry fault current or due to neglected /unprotected overloading of the cable or due to high armour currents caused by power thefts where only phase(s) are unauthorisely tapped & at the point of poer consumption earth terminal is established by burring underground a not so good earthing rod (or using an underground water pipe for the purpose)
1 4041Post New Electrical Engineering Questions
WHAT IS SUBSTATION & ACCORDING TO VOLTAGE HT,EHT SUBSTATION EXPLAIN IT
What Is Connection APFC Panel In Compony.
how we calculate the short circuit capacity of the busbar in LV & HT?
How to select circuit breakers rating eg. if i select a circuit breakers of capacity 40 amps DC with operating voltage 28 volts and if i what to use same circuit breakers for 300 Volts DC application what is the current rating of this circuit breakers.
could anybody able 2 send me jindal steels previous papers fr electrical steam....pls send 2 my id if possible....sirisha.shaik@gmail.com
A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.
How do u analyse protection fault when vcb tripping on load
How much ph is maintained of water electrolyte which is used in LRS for 1200 kw slipring induction motor ?
What is the type of earth fault protection used in battery? explain.
WHAT IS THE FUNCTION OF SHORT CIRCUIT MAINTENANCE CT
what is saturation kit?which use above 15 kw motors panel side.
What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?
which is better to use svc or synchronous condenser why ?
How to confirm the Phase shifting Transformer VECTOR GROUP relation , as below ZNy11.45d10.45-ZNYy0.15d11.15
What is force on a conductor in a magnetic field ?