Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

can induction motor becomes as a generator. if yes how it is possible. if there is a squirrel cage rotor.

6 12510

I am interested to know what does 15 KVA DG set actually means? If I dont know the DG rating, is it possible to identify KW by simply knowing the diesel consumption?

2251

how system fault level is calculated?

HCL,

1 6543

how braking & making capacity of circuit breaker is calculated?

2048

How the soft starter control the starting current in three phase squirrel cage AC Motor?

1 3585

What makes the difference between 50Hz supply and 60Hz supply which one is economical? What is the use of using increased frequency?

ABB,

5 11012

could anyone suggest project title

Engineering,

1 4318

What voltage is used in Directional earth fault relay? and why?

L&T,

5 12234

Why does inductor is connected to dc supply? or what is the role of an inductor when connected to DC source?

TCS, TRR,

3 10486

why ac generator ratings in kva only why not kw ????????????? ?

7 13840

tell me exact relation b/n voltage and current and which one is depend other

HAL,

7 9384

without any excitation we can strt any dc or ac moter?

Bhel,

6 12845

why transformer are rated in KVA not in watt?

DMRC, L&T, TCS,

7 18329

Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.

Megatron Solutions, TCL,

2181

what is the distance maintained between the power and data cables with respect to the KVA .... plss give me the formula

1 4262


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

why dc is used in control circuits for MV & LV switchgeras instead of ac

2021


if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .

1715


hi, i finished b.tech eee in 2008, im worked in dg sets mfg company , now i left job in 6months back, now again i want get job core side, how can i get? is there any couses we have learn to get better oppurtunity? /

2034


What is the actual calculation for transformer short circuit test?.

2519


The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?

2381


May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?

1562


we use capister for power factor. when we use capaciter in dg circuit  than defect dg. can we use capaciter bank for dg circuit

1982


what causes contact chatter when there is no demand on the air conditioning unit?

2097


Why field rheostat is kept in minimum position?

1328


What is meant by coupling capacitor?

1130


1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?

1909


how many stairs have you climbed while you were coming

2234


does buccholz in a transformer use batteries

4980


What will be result if we connect LT votage to the terminal of HT motor?

2194


how to calculate the distance relay faulty zone?pls explain?

2104