Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
2281i install a DP transmitter of Faugi on drum level of boiler but i face a problem in it when i engergize the transmitter the meter shows 0 or 100% no variation in it.the distance of two points is 19.5 inches, i am in trouble please suggest me what can i do it's very urgent Please reply me as soon as possible Best regards ikraam haider
5 8270How can you derive a composite matrix for reflecting an object in 3D about any arbitrary plane characterised by normal vector N?
1 3646What are the reason of unbalanced secondary voltage of HT transformer 33kv/6.6kv ? Incomming voltage is balanced.33kv each secondary voltage 6.6 kv 6.4 kv 6.4 kv At no load conditions.
1 3942why the thermocouple is a transducer an Rtd is not a transducer both taking heat as a input and give millivilt and ohms plz give me answer
2 11917
Why it is a preferable option in parallelextender development ?
Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not
how to work droop ct in generating station
When did national commission for space research institute thumba equatorial rocket launching station commissioned ( terls )?
How can we demolish concrete beams?
What is motion balance principle?
can you plz send l&t aptitude questions if available its urgent plz plz plz
What is capacitor?
what is Clear Ice?
how a dpad circuit works
How the current is reduced to zero in a photodiode?
how to choose cable size with respect to load? how to convert cable size in mm2 to sq.mm?
What is a waveform used for in reference to electronics?
What is enzyme?
any one can explain the stages of a knee point which is taken during ct magnetising curve.