Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) For the purpose of inflating car tyres, spray painting, etc. i.e. say a small workshop, what size of a compressor (CFM) is recommended? It will be generally for a hobby use and not commercial use.
1 4445In a transformer, the hysteresis and eddy current losses depend upon 1.load current 2.maximum flux density in core 3.type of lamination 4.supply frequency The correct statements are (a) 1 and 3 (b) 2 and 3 (c) 1 and 4 (d) 2 and 4
9 131911.why ACB is not connected in HT side what Happens? 2.how much voltage maintained in ACB breaker? 3.OLTC is connected in primary side in case secondary side connected what happened?
L&T,
3 8796i want to run 11kv star connected motor in 6.6kv with delta connected throught inverter, is it possible?
1990
02. a. The diagonal of a 9 cube…………… 1 b. Surface area of 9 cube…………… 1 c. Volume of 1-3 cube …………… 1 d. Compressive area of 6 cube …………… 1 e. Top & Bottom face of a Cylinder/Cube is to be proper leveled to deliver the…………………………..…… properly.
rrbchennaimodel question paper for current papers
Explain GPRS architecture.
What is ditching?
What are the characteristics of scr?
What is iron ferite? Where is it used?
Explain the working of voltage commutated chopper with aid of circuit diagram and necessary waveforms. Derive an expression for its output voltage?
question no. 4======Give a brief description of the following terms: a) Play head b) Symbol c) Tweening d) ActionScript e) Frame rate f) Library panel g) Masking h) Context – sensitive Property Inspector i) Bandwidth Profiler j) Frame Label
Work done in a free expansion process is
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
What do you measure in the banana and mountain diagram?
What are the different methods of firing circuits for line commutated converter?
What is the difference between uv and ir scanners? and what is the workig principle of both
What is the normal phase difference between the voltage and the no-load current in a transformer?
DEAR SIR,I GOT THE CALL LETTER FROM RRB, SECUNDERABD AS A JE-II SO PLEASE PROVIDE ME SOME MODEL QUESTION AND ANSWER PAPERS AND LAST YEAR QUESTION PAPERS