Engineering AllOther (1379) what is the significance of 3.5 core cable? or what does this half core mean and why is it required?
5 17314single phase can run in PVC conduit. Three phase can also run in one PVC conduit. But two phase cannot run in one PVC conduit. WHY? reply plz....awaiting your answer.
L&T,
8 18048what is the difference between electrical and electronic choke.. and whats the main advantage of elecronic choke?
5883iam working as field engineer since 3 years so what is the appropriate answer for changing company i'e., why do u want to change ur present company
1 3319my company total load is 1000kw, 415volt, all load are inductive load. incoming powerfactor is .8. we want to have0.95 pf connecting capacitors. so now how much rating of capacitors we have to connect? show how?
3 6354
Explain how the lubricating oil circulates in a diesel engine.
we have 3.5MVA-11/6KV transformer. how can we calculate earth fault current and NGR calculation?
what is the best transformer oil breakdown voltage?
I Want To Know Quantity of Cement Conc. & Sand in Column of 9"x9"x10'
Why 15Amp. MCB is suitable to carry load of 1.5Ton Ac please Explain?
What is a process flow diagram?
would you please give me any idea about the BARC interview question on electrical? i have an interview on 1st july.....plz hlp me.......its urgent......
pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.
How many types of slabs are there & how to design it?
Dear sir my name Ankit i m Diploma holder present working in Welspun Corp ltd Anjar as Asst.engg (salary 14400/month ctc) i Would like to change my company also i have selected in ford India pvt ltd Sanand as trainee Tech with salary 12000/month so please suggest me for changing my job hope for *ve response
Why neutral is not used in three phases dol starter
Why you consider yourself suitable for the post
The building has 12 columns of 12x9 in 3 rows of 4 each in a plot of 50'x30', The central row is strengthened with 16mm twisted rods. The roof area is 1500 sft including balconies. calculate the load factor per sft. Also indicate the number of roofs the building can withstand.
How will you calibrate PID controller? explain with example.
How cooling Tower height selected