capacitor is load free component but why ampare meter shows the current when the capacitor bank breaker close?
4 9141capacitor is load free component but why ampare meter shows current when capacitor bank breaker close?
5 15369why in three phase 440 circuit in all phase current is almost equal L1-35 A,L2-34 A ,L3-31 A but in nutral when i check with clamp meter it shows 25 A?
4 13239why for transformer protection we protect tranformer from 3rd hormonics and 5th hormonics and what is the reason of generating these horminics in electrical system?
2 9714what is difference between start imitation and start interlock for 3 phase motor protection ?
2 7905what is difference between differential protection and distance protection and how we calculate the sloop?
5 46115how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?
2889Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?
4323How do u prepare Cost sheet? on what basis it is prepared how it is useful to the management?
3 9633how to calculate restraing current and operating current for differential protection if 20 mva transformer is OLTC 33 kv/11 kv ? and what should be the type and ratio of CT?
2 6027Post New OPS Interview Questions
How do I insert an image?
How to create a scrollable cursor with the scroll option?
Differentiate between induced emf and self inductance?
Explain sql server service broker?
What does html5 mean?
How do I add and remove categories in wordpress?
How to list all schemas in a database?
What is ordered map in java?
i have done B.TECH in che.tech.and doing MBA . why you doing mba why u have not join any job.
What is the precedence of stage variables,derivations, and constraints?
Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75
The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is:
WARNING: Could not connect to equalize destination. (7001)
Retrying. Number of retries = 0/1
ERROR: LdXopsLoadMain: connect error 10060
ERROR: Processing terminated due to connection error. (7002)
Equalization end with errors. STN0149
---- ERROR = 2 WARNING = 1 ----
Background:
>Updated the ExaOPC software on the STN from 3.60 to 3.75
>STN operating system is Windows Server 2008 R2
>HIS operating system is Windows Server 2016 Stanard
Solutions attempted include:
>Ensuring all IP addresses are correct and all networked devices can be pinged.
>The ability to ping a device using its host name from another device (