OPS Electrical Engineering Interview Questions
Questions Answers Views Company eMail

capacitor is load free component but why ampare meter shows the current when the capacitor bank breaker close?

4 7247

capacitor is load free component but why ampare meter shows current when capacitor bank breaker close?

5 13443

what is difference between AC VVVF drive & Dc VVVF drive explain their working principle?

13 43840

why in three phase 440 circuit in all phase current is almost equal L1-35 A,L2-34 A ,L3-31 A but in nutral when i check with clamp meter it shows 25 A?

4 11737

why for transformer protection we protect tranformer from 3rd hormonics and 5th hormonics and what is the reason of generating these horminics in electrical system?

2 8526

what is difference between start imitation and start interlock for 3 phase motor protection ?

2 6952

what is difference between differential protection and distance protection and how we calculate the sloop?

5 43644

how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?

2510

why voltage rating not mention at HPSV or HPMV lamps?

2 5877

can we use HPSV LAMP in HPMV LAMP fixture ?and viseversa.

5 11885

Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?

3847

how to calculate restraing current and operating current for differential protection if 20 mva transformer is OLTC 33 kv/11 kv ? and what should be the type and ratio of CT?

2 4980

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage.

1 4039

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

1744

Post New OPS Electrical Engineering Interview Questions


OPS Electrical Engineering Interview Questions


Un-Answered Questions

Explain what does the conf.setmapper class do?

344


How do you change a file format in excel?

323


how to tie 10 legged stirrups

5895


What do you understand by unit and ()in scala?

292


If an application has multiple classes in it, is it okay to have a main method in more than one class?

538






how can we select the appropriate VCB ?

1826


WHAT IS THE BANK RECONSILATION, WHAT THE FORMAT OF IT

1733


State the relation between EME, GDE and Co-operating system?

674


How do you insert a listbox in excel?

351


How to rename a file in linux?

450


What is object and example?

604


What is difference between Trace and Debug

550


What are the types of relationships applicable to salesforce?

182


Explain, why is rdbms better than dbms?

503


What are the diff types of exception?

563