Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

OPS Interview Questions
Questions Answers Views Company eMail

why in three phase 440 circuit in all phase current is almost equal L1-35 A,L2-34 A ,L3-31 A but in nutral when i check with clamp meter it shows 25 A?

4 13213

why for transformer protection we protect tranformer from 3rd hormonics and 5th hormonics and what is the reason of generating these horminics in electrical system?

2 9694

what is difference between start imitation and start interlock for 3 phase motor protection ?

2 7891

how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?

2884

why voltage rating not mention at HPSV or HPMV lamps?

2 6768

can we use HPSV LAMP in HPMV LAMP fixture ?and viseversa.

5 13692

Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?

4312

how to calculate restraing current and operating current for differential protection if 20 mva transformer is OLTC 33 kv/11 kv ? and what should be the type and ratio of CT?

2 6010

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage.

1 4723

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2210

Post New OPS Interview Questions




Un-Answered Questions

how to create subdomain routing in laravel 5?

788


What is a simple calculation?

697


What are latent semantic indexing keywords?

859


Can you explain what are the changes presented by actionscript?

848


In which language, backbone js is written?

5


What is the use of runnable interface?

1163


what is the correct method for the outdoor termination of 19/33 KV HT cable step by step?

2071


Do you know the concept of Diminishing Marginal Utility?

966


Why c++ is so important?

1077


What is the document change rule?

642


What is a java ee container?

868


What is pop in python?

781


What is embedded sql in db2?

1004


Introduce yourself please?

1227


Describe the concept of “region”.

935