Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Company Name Starts with ...
#  A  B  C  D  E   F  G  H  I  J   K  L  M  N  O   P  Q  R  S  T   U  V  W  X  Y  Z

OPS Interview Questions
Questions Answers Views Company eMail

why in three phase 440 circuit in all phase current is almost equal L1-35 A,L2-34 A ,L3-31 A but in nutral when i check with clamp meter it shows 25 A?

4 13242

why for transformer protection we protect tranformer from 3rd hormonics and 5th hormonics and what is the reason of generating these horminics in electrical system?

2 9716

what is difference between start imitation and start interlock for 3 phase motor protection ?

2 7907

how we can adjust for three phase motor cold stall time ,hot stall time and thermal register set up?

2889

why voltage rating not mention at HPSV or HPMV lamps?

2 6782

can we use HPSV LAMP in HPMV LAMP fixture ?and viseversa.

5 13733

Why Transformer Neutral having one earth pit ( more earth electrode resistance) whereas body have many earth pit ( less earth electrode resistance)?

4324

how to calculate restraing current and operating current for differential protection if 20 mva transformer is OLTC 33 kv/11 kv ? and what should be the type and ratio of CT?

2 6035

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage.

1 4737

how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2214

Post New OPS Interview Questions




Un-Answered Questions

What is display:block and display:none?

945


What is difference between vlookup and hlookup?

625


Can soap use json?

810


What the best way to inject one service into another in angular 2?

828


Why python is called portable?

982


Tell me the use of keyword with encryption. Create a store procedure with encryption?

1008


What is the difference between $scope and scope in angular?

868


In double bond, how many sigma and Pi bonds are present in it?

1073


What is bazel and closure compiler in angular6?

781


Does sap vora work with relational data-bases other than sap hana? : hana vora

81


Is Python necessary for machine learning?

110


Explain route configuration?

836


Explain the Realisation concept and Accounting concept? why do you prepare p/l appropriation account? 4 difference b/w public and private caompany? How do you calculated closing stock in tradind a/c? Contents an invoice receipt? classification of Error as per accounting? Diff btwn Satutory audit & Internal audit? Diff b/w reserves for bad debts and provision for bad debts? Where the Bank book and the Cash book will not reconcile? When will the Cash book have a credit balance?

2803


What does join () do in python?

826


What is activatedroute in routes?