Answer / ka
in a fixed beam the fixed ends are restrained from rotation
as a result of which a reacting moment is created but in
simply supported beams the supports are free to rotatein
the plane of action of load so there does not exist any
reacting moment
| Is This Answer Correct ? | 43 Yes | 4 No |
Answer / dunstan
fixed end are restrained for all degree of freedom
therefore create moment, but simply supported end(pin
joint)is free for rotation. therfore no moment.
| Is This Answer Correct ? | 22 Yes | 2 No |
Answer / ppl
Positive moment (with tension in the bottom) is created in
both simply supported and fixed beams which are loaded by
gravity. However, this moment is less in fixed beams, since
a fixed support is made to resist some of the moment in the
beam. As the other answers partially said, negative
moment(with tension in the top) is only created in fixed
beams because of the moment resistance in the connections.
True simply supported beams do not have negative moment
because by definition, their connections do not resist moment.
| Is This Answer Correct ? | 10 Yes | 1 No |
in case of fixed baem, both ends of beam are fixed & in order to make unit slopes in the end ,moment is acted..but in case of simply supported beams as ends are free ,therefore no moment is acted.
| Is This Answer Correct ? | 1 Yes | 11 No |
What are the advantages of cad?
hi, i am doing my B.tech third year and i want to have a job in Genpact...So can you help me which kind of job would be more appropriate for me in such a company and How should i prepare for an interview?
how do we design mix ratio?
SHEAR FORCE AND BENDING MOMENT DIAGRAMS
human blood is newtonian or non- newtonian fluids
what is the difference between composition of ceramic & glazed tiles?
what"s the merits and demerits of hollow blocks comapre than to bricks?
Find out Cutting Length of Steel for Right angle Triangle? Where Opposite Side 4m, Adjacent side 6m. (Assume cover 40mm)
What are the precautions needs during concrete pouring in very hot weather?
What is the cement and sand consuption of 1:4 block work
Engineering method, why need is column kiker??? what is necessity??
uses of M50 and M60 grade ordinary and pozzolona portland cement concrete?
Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)