Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Weight balance variation limit during analysis

Answers were Sorted based on User's Feedback



Weight balance variation limit during analysis..

Answer / srinivas

Balance variation for analysis 10% for both solids and liquids according pharmacopoeia

Is This Answer Correct ?    21 Yes 0 No

Weight balance variation limit during analysis..

Answer / neeraj

Balance variation limit is 10% for solid as well as liquid

Is This Answer Correct ?    3 Yes 0 No

Weight balance variation limit during analysis..

Answer / bharat

+, - 10%

Is This Answer Correct ?    1 Yes 0 No

Weight balance variation limit during analysis..

Answer / penchal reddy

As per USP Below 100 mg weighed 10%
Liquids 10%

Is This Answer Correct ?    0 Yes 0 No

Weight balance variation limit during analysis..

Answer / shankesh patil

10 % is acceptable

Is This Answer Correct ?    0 Yes 0 No

Weight balance variation limit during analysis..

Answer / neraj kumar

For solid 10 % & liquid 20 %.

Is This Answer Correct ?    0 Yes 0 No

Weight balance variation limit during analysis..

Answer / kambam raveendra reddy

for solids 5% and for liquids 10%

Is This Answer Correct ?    1 Yes 9 No

Post New Answer

More Analytical Chemistry Interview Questions

In Agilent HPLC calibration using Empower 3 Software, What is the criteria for GPV Baseline starting point? i.e., Either it can start from -0.00/+0.00 or any range is there like -0.05 to +0.05 or ......etc?

1 Answers   Apotex,


what is diffrence between Specific optical rotation, optical rotation?

3 Answers  


How to prepare ppm solution of Nacl form its salt?

5 Answers  


What is the column performance and column efficiency?

2 Answers   Reddy Labs,


if partition coefficient value was positive means, what it indicates ?

1 Answers  


Is sonication essential in solubility testing of a drug substance?

6 Answers   Aurobindo,


why RID detector is used for selective materials like Mannitol, Hydroxyethyl Starch and Sorbitol?

5 Answers  


can some other acids like nitric acid or HCl can be used in the calibration of UV.Vis. spectrophotometer????

2 Answers   Cipla,


In GC, What does 'Column condensation test' mean by?

2 Answers   Reddy Labs,


what is difference between UV - VISIBLE MODEL NO like 1600,1601,1700 etc ? plz explain me

0 Answers   Graviti Pharmaceuticals,


what is the diference between spectroscopy and chromatography

2 Answers   Cipla, PharmChem, Reliance,


what is the definition of limit of stray light in UV calibration

1 Answers   FDC, Zydus Cadila,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)