why RID detector is used for selective materials like
Mannitol, Hydroxyethyl Starch and Sorbitol?

Answers were Sorted based on User's Feedback



why RID detector is used for selective materials like Mannitol, Hydroxyethyl Starch and Sorbitol?..

Answer / satheesh kumar

Since RI detectors useful for type of compounds such as
carbohydrates (Non-UV Absorbing Substance)Also,Each
compounds have it's own refractive Index.Hence it is useful
for Non-UV Absorbing substances.

Secondly,It's applicable only in isocratic mode.

Is This Answer Correct ?    7 Yes 0 No

why RID detector is used for selective materials like Mannitol, Hydroxyethyl Starch and Sorbitol?..

Answer / m.sivalingeswararao

These compounds are Saturated hydrocarbon products.
As UV-Light absorption is found in Unsaturated compounds not in saturated compounds,hence need to go for another appropriate technology, here it is RID

Is This Answer Correct ?    4 Yes 0 No

why RID detector is used for selective materials like Mannitol, Hydroxyethyl Starch and Sorbitol?..

Answer / jeff

because those chemicals don't have UV absorption or very low
absorption in UV range.

Is This Answer Correct ?    3 Yes 0 No

why RID detector is used for selective materials like Mannitol, Hydroxyethyl Starch and Sorbitol?..

Answer / sivanseyal g

detectors (RID) are widely used for many substances, such as to analyze components with low UV absorption, but it requires time for the baseline to stabilize,

Is This Answer Correct ?    0 Yes 0 No

why RID detector is used for selective materials like Mannitol, Hydroxyethyl Starch and Sorbitol?..

Answer / t

Hi

Is This Answer Correct ?    0 Yes 10 No

Post New Answer

More Analytical Chemistry Interview Questions

what is impurity profile. how to interpret this impurity profile to a drug product or drug substance.

0 Answers  


Is it necessary to inject three replicate for accuracy in AMV.

1 Answers   Amoli Organics,


why we use deturium lamp in uv spctrophotometer other than lamps

1 Answers  


what is different when impergnated silica plates are used in separation of azo dyes using column chromatography?

0 Answers  


WHAT IS PVT TEST IN DISSOLUTION TEST , WHAT IS PVT SIGNIFICANCE AND HOW IT IS PERFORMED ?

1 Answers  






Why do we use 0.005M h2so4 solution for preparation of k2cr2o7 solution for UV calibration?

3 Answers   Jubilant, Medreich, Mylan,


what is specificity?

4 Answers   Amneal Pharmaceuticals, Aurobindo,


why deutiriated chloroform used in NMR for sample prepration. what reaction takes place.give reasons

1 Answers  


which light is used in FT-IR spectroscopy

6 Answers   Hetero,


Why we use potassium dichromate in uv calibration Exact reason behind it??

0 Answers  


differnc btw c18 and c-8 column

3 Answers   Cipla,


What is UV cut off?

1 Answers   Sanmar,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)